My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_FILE 14
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
15999
>
2300 - Underground Storage Tank Program
>
PR0231945
>
COMPLIANCE INFO_FILE 14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/22/2022 2:35:55 PM
Creation date
6/3/2020 9:55:33 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
FILE 14
RECORD_ID
PR0231945
PE
2361
FACILITY_ID
FA0003934
FACILITY_NAME
Lawrence Livermore National Lab - Site 300
STREET_NUMBER
15999
Direction
W
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
15999 W CORRAL HOLLOW RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231945_15999 W CORRAL HOLLOW_FILE 14.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
385
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County, .� <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 3 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.si oq v.org/ehd <br />and Sty, <br />.a,. <br />Facility Name: Facility Address: Date: <br />LAWRENCE LIVERMORE NATIONAL LAB- 15999 W CORRAL HOLLOW RD, TRACY August 01, 2017 <br />wx <br />_ <br />Wr <br />323 HSC 25283.5(a) <br />Unburied below grade UST system failed to meet exemption status <br />❑ V ❑ R <br />❑ COS <br />324 <br />CCR 2717.1(g) <br />Tampered with red tag <br />❑ V ❑ R <br />❑ COS <br />325 <br />CCR 2717.1(f) <br />Deposited petroleum into a red tagged UST <br />❑ V ❑ R <br />❑ COS <br />326 <br />HSC 25299(a)(9) <br />Tampered with or disabled leak detection devices or alarms <br />❑ V ❑ R <br />❑ COS <br />327 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />❑ V ❑ R <br />❑ COS <br />328 <br />HSC 25298 <br />Failed to comply with temporary closure requirements <br />❑ V ❑ R <br />❑ COS <br />329 <br />HSC 25298 <br />Failed to comply with permanent closure requirements <br />❑ V ❑ R <br />❑ COS <br />330 <br />CCR 2636(f)(6) <br />Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system <br />❑ V ❑ R <br />❑ COS <br />10 "Nma <br />401 CCR 2636(a)(3) <br />Suction piping not properly sloped or incorrectly located check valve ❑ V ❑ R <br />❑ COS <br />402 CCR 2643(d) <br />Daily monitoring of suction pipe (pre -Jan 1984) not performed ❑ V ❑ R <br />❑ COS <br />403 CCR 2643(d) <br />Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1984) ❑ V ❑ R <br />❑ COS <br />404 CCR 2643(e) <br />Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) ❑ V ❑ R <br />❑ COS <br />ollt <br />2010 See below <br />Unlisted Administration/Documentation violation ❑ V ❑ R <br />❑ COS <br />2030 See below <br />Unlisted Operations/Maintenance violation ❑ V ❑ R <br />❑ COS <br />2060 See below <br />Unlisted Design/Construction violation ❑ V ❑ R <br />❑ COS <br />Item # Remarks <br />210 CCR 2715(e) Designated operator monthly inspection reports not maintained on site for at least 12 months. <br />The January 2017 designated operator monthly inspection report was not found on site. Designated operator <br />monthly inspection reports for the previous twelve months shall be retained on site. Locate and ensure that copies <br />of the previous twelve months of designated operator monthly inspection reports are maintained on site. <br />This is a minor violation. <br />Overall Inspection Comments: <br />This report has been amended from its original version issued on August 01, 2017. This amended report <br />supersedes any previous versions. <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork within 30 days of receipt of this report. <br />Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br />documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br />Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br />applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br />FA0003934 PR0231945 SCO01 08/01/2017 <br />E H D 23-01 Rev. 09/22/16 Page 3 of 4 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.