Laserfiche WebLink
CLOSURE REPORT FOR UNDERGROUND STORAGE TANK 827-DlU1 <br /> The concrete tank anchoring structure(s)was disposed of with the soil: <br /> [ ]Yes [ ] No [ ] Left in the Tank Excavation [X]N/A <br /> If no,describe how the concrete tank anchoring structure(s)was disposed of: N/A <br /> Name and address of disposal facility: N/A <br /> Additional native soil removed as part of a remedial effort: [X]Yes [ ]No <br /> Soil was removed due to approximately 10-gallons having spilled from the tank during <br /> excavation Additional soil was removed due to the detection of an apparent odor,unrelated <br /> to the spillage Ap=proximately 20 cubic yards total were removed after the tank was <br /> excavated <br /> [N/A] LLNL Hazardous Waste Requisition and Uniform Hazardous Waste Manifest"TSD <br /> Facility to Generator"copy for the soil enclosed. <br /> Volume of native soil removed: see next)* cubic yards. <br /> Volume of backfill removed: 120*cubic yards. [*Combination of native and backfill material] <br /> Describe how the excavated soil was handled (i.e. how and where it was stored): The soil was <br /> stockpiled on and covered with visc'ueen The stockpiles are located by the gate north of <br /> B827A and south of B827A behind the 827-DlU1 excavation at Site 300. <br /> Soil or backfill returned to the tank excavation or piping trench: [ ]Yes [X]No <br /> If yes,volume of soil returned to the excavation: N/A cubic yards <br /> Reason for the return of the soil to the tank excavation or piping trench: N/A <br /> ENVIRONMENTAL SAMPLE INFORMATION: <br /> SOIL <br /> Soil sample collection and handling procedures were in accordance with LLNL Tank <br /> Assessments and Guidance Group Procedure 203,Soil Sampling. <br /> Soil samples were collected by: Marion Heaton,LLNL Date: 3/11/94 <br /> Sample analyses requested: Tank Excavation (TPH Diesel and BTXE)• Stockpile (TPH Diesel; <br /> BTXE• EPA Method 8010/8020 Metals by STLC/TTLC• and Reactivity Corrosivity, and <br /> Ignitability (RCI))• and Buildings 827 836 and 879 tank removal stockpiles composited for <br /> gross alpha & beta tritium and gamma spectrometry. Samples collected for disposal <br /> options included 1 discrete sample collected for each 25 yards <br /> TPH-D•Total Petroleum Hydrocarbons as Diesels BTXE• Benzene Toluene Xylenes and Ethyl Benzene; <br /> HVOC EPA Method 8010 for Halo=ated Volatile Organic Carbons• AVOC• EPA Method 8020 for Aromatic Volatile Organic <br /> Carbons, STLC• Soluble Threshold Limit Concentration; TTLC•Total Threshold Limit Concentration <br /> Name and address of analytical laboratory: California Laboratory Services, 3249 Fitzgerald <br /> Road Rancho Cordova CA 95742 [Radiological analyses on stockpile composite samples <br /> were performed by LLNL Environmental-Analytical Sciences Lab]. <br /> Describe how the tank excavation was secured after soil sample collection: The excavation was <br /> secured by means of yellow plastic "snow fence" and barricades equipped with flashing <br /> lights The excavation was then filled with imported clean fill. <br /> WATER <br /> [X] Not applicable. (No water in the tank excavation or piping trench) <br /> Static water level below grade: N A feet <br /> Describe any sheen,free product or odor present in the water: None present. <br /> Water pumped out of the excavation:[ ] Yes [X]No <br /> Volume of water removed from the tank excavation: N/A gallons <br /> Water sampled: [ ]Yes [X]No <br /> Water sample was collected by: N/A Date:N/A <br /> Sample analyses requested: N/A <br /> Name and address of analytical laboratory: N/A <br /> Describe how the water was sampled: N/A <br /> Identify the source of the water(if known): N/A <br /> Describe where and how the removed water was stored on site,and type of containment used: <br /> N/A <br /> 3 <br /> i <br />