Laserfiche WebLink
GOVERNING • SSS <br />1. National Fire Protection Association (NFPA 30): Flam- <br />mable and Combustible Liquids Code <br />2. Underwriters Laboratories Listing: UL Labels shall be <br />affixed to control unit indicating a total system listing (not <br />0 <br />PPM Series Computers: PPM 2000/PPM 2000-232 <br />PPM Series Auxiliary Controllers: PPM 2100/PPM 3200/ <br />Four Zone Liquid Control/Multiplexer <br />Temperature Range: Computers 32 to 120°F. Auxiliary Con- <br />trollers -20 to 150°F. <br />Mounting Environment: Must be mounted in a dry, non- <br />hazardous environment. Template provided. <br />Computer Power (and Multiplexer): 120 VAC, 500mA, <br />supplied by a separate UL Listed receptacle mounted 14 VAC <br />transformer (provided). <br />Auxiliary Controller Power (2100): 120 VAC, 500mA, sup- <br />plied by a separate UL Listed receptacle mounted 12 VDC <br />power supply (provided). (3200): 115 VAC. (Four Zone <br />Liquid Control): 14 VAC from PPM computer. <br />Probes: Intrinsically safe for use in NEC, Class 1, Division 1, <br />Group D environments. Located within 2000' of controller. <br />Each probe and probe channel contain both vapor and water <br />sections. Each probe channel can be programmed for vapor <br />(PPM alarm levels), water/conductivity and/or high/low level <br />probes. <br />Cable: Maximum 1000' length from power to control unit -16 <br />11 <br />individual component listing). <br />3. Environmental Protection Agency meets and exceeds <br />regulations 280.41 (a), (b), 280.43 (e), (g), 280.44 (b), (c), <br />280.45 (b). <br />Expandable to 32. <br />Communications Specifications: <br />Modem Format — Hayes, Compatible Auto Answer <br />Baud — 1200 <br />Character Set — Async. ASCII <br />Bits per Character — 8 data bits, 1 stop bit <br />Parity — None <br />Enclosures: Painted 16 gauge custom with lock and conduit <br />access knockouts. <br />Enclosure Dimensions: Width 8.0 " x height 12.0 " x depth <br />4.0" <br />Computer Wiring Access: Three knockouts are provided for <br />3/4" conduit fittings. Each knockout accesses an isolated <br />section of the computer. No drilling is permitted. <br />Access One: Power supply wiring (3 conductor, 16 gauge <br />minimum). This wiring must be in dedicated conduit. <br />Access Two: Dry contact wiring. This access is used for <br />auxiliary controllers. Dedicated conduit without junction <br />boxes is required. <br />Access Three: Probe wiring, channels one through four. <br />Channels are dual purpose (both vapor and water). <br />Dedicated conduit is required. Intrinsic Safe Wiring labels <br />must be placed on all junction boxes (provided). <br />gauge minimum. Maximum 2000' from control to probes -18 PPM Series Optional Communications Software: <br />gauge minimum. RECON Data Acquisition Software <br />IBM compatible <br />Channels (PPM2000/2000-232): 4 probe channels available. 640K required <br />Controller Contacts Used With <br />PPM 2100 4 (1 alarm/channel) PPM 2000-232 <br />1 (any channel alarm) <br />PPM 3200 <br />1 (2 Form C any channel) <br />10 amp at 115 VAC <br />1. Red Jacket Electronics, Marley Pump Company, 5800 <br />Foxridge Drive, Mission, Kansas, 66202. <br />PPM 2000 <br />PPM 2000-232 <br />PPM 3000 <br />Multiplexer <br />RED JACKET" <br />RJE-22 <br />0 6/89 <br />