FIED PROGRAM CONSOLIDATED FOIq <br /> TANKS <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 1 <br /> (two pages per tank) <br /> Page_of_ <br /> TYPE OF ACTION ❑1 NEW SITE PERMIT ❑ 4 AMENDED PERMIT ® 5 CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br /> (Check one item only) ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ❑ 3 RENEWAL PERMIT (Specify reason-for local use only) (Specify reason-for local use only) ❑ 8 TANK REMOVED 430 <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) FACILITY ID: 1 <br /> 3 <br /> ConocoPhilli s Site#2705446 <br /> LOCATION WITHIN SITE(Optional) 431 <br /> 1403 Country Club Boulevard, Stockton, CA 95204 <br /> TANK ID# 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK Yes Z No 434 <br /> 4 Unknown <br /> If"Yes",complete one page for each compartment. <br /> DATE INSTALLED(YEAR/MO) 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> 01/01/1991 1 2500 <br /> ADDITIONAL DESCRIPTION(For local use only) 438 <br /> r <br /> TANK USE 439 PETROLEUM TYPE 440 <br /> ❑1. MOTOR VEHICLE FUEL ❑1a. REGULAR UNLEADED ❑2. LEADED ❑5. JET FUEL <br /> (If marked complete Petroleum Type) [11b. PREMIUM UNLEADED ❑3. DIESEL [16. AVIATION FUEL <br /> ❑2. NON-FUEL PETROLEUM ❑1c. MIDGRADE UNLEADED ❑4. GASOHOL ❑99.OTHER <br /> ❑3. CHEMICAL PRODUCT COMMON NAME (from Hazardous Materials Inventory page) 441 CAS#(from Hazardous Materials Inventory page) 442 <br /> ®4. HAZARDOUS WASTE Waste Oil <br /> (Includes Used Oil) <br /> ❑95.UNKNOWN <br /> TYPE OF TANK 1. SINGLE WALL 0 3.SINGLE WALL WITH 0 5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Check one item only) EXTERIOR MEMBRANE LINER ❑95. UNKNOWN <br /> ®2. DOUBLE WALL [14. SIGNLE WALL IN VAULT ❑99. OTHER <br /> TANK MATERIAL-primary tank ®1. BARE STEEL 0 3. FIBERGLASS/PLASTIC 0 5. CONCRETE 95. UNKNOWN 444 <br /> (Check one item only) ❑2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS [18. FRP COMPATIBLE W/ ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) 100%METHANOL <br /> TANK MATERIAL-secondary tank 0 1. BARE STEEL 10 3. FIBERGLASS/PLASTIC 0 5. CONCRETE ❑95. UNKNOWN 445 <br /> (Check one item only) ❑2. STAINLESS STEEL ❑4.STEEL CLAD W/FIBERGLASS ❑8. FRP COMPATIBLE ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) W/100%METHANOL <br /> ❑5. CONCRETE ❑10.COATED STEEL <br /> TANK INTERIOR LINING ❑1.RUBBER LINED ❑3.EPDXY LINING ❑5.GLASS LINING ®95.UNKNOWN 446 DATE INSTALLED 447 <br /> OR COATING ❑2 ALKYD LINING ❑4 PHENOLIC LINING ❑6 UNLINED ❑99 OTHER <br /> (Check one item only) (For local use only) <br /> OTHER CORROSION ❑1 MANUFACTURED CATHODIC❑3 FIBERGLASS REINFORCED PLASTIC ®95 UNKNOWN 448 DATE INSTALLED 449 <br /> PROTECTION IF APPLICABLE PROTECTION ❑4 IMPRESSED CURRENT ❑99 OTHER <br /> (Check one item only) ❑2 SACRIFICIAL ANODE (For local use only) <br /> SPILL AND OVERFILL YEAR INSTALLED 450 TYPE(local use only) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> (Check all ❑1 SPILL CONTAINMENT <br /> that apply) ❑1 ALARM ❑3 FILL TUBE SHUT OFF VALVE <br /> ❑2 DROP TUBE ❑2 BALL FLOAT ❑4 EXEMPT <br /> ❑3 STRIKER PLATE <br /> E tee,• ,x. �,U > ,5- � <br /> IF SINGLE WALL TANK(Checkallthatapply) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> (Check one Item only) <br /> ❑1 VISUAL(EXPOSED PORTION ONLY) ❑5 MANUAL TANK GAUGING(MTG) ❑1 VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2 AUTOMATIC TANK GAUGING(ATG) ❑6 VADOSE ZONE ®2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3 CONTINUOUS ATG ❑7 GROUNDWATER ❑3 MANUAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑8 TANK TESTING <br /> +(SIR) BIENNIAL TANK TESTING ❑99 OTHER <br /> M INN: <br /> \ . <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCE 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> REMAINING <br /> gallons [:]Yes ❑ No <br /> UPCF(1/99 revised) Formerly SWRCB Form B <br />