COMPLIANCE INFO_1999-2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3250
>
2300 - Underground Storage Tank Program
>
PR0232224
>
COMPLIANCE INFO_1999-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2021 10:42:38 AM
Creation date
6/3/2020 9:56:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2010
RECORD_ID
PR0232224
PE
2361
FACILITY_ID
FA0001877
FACILITY_NAME
AM PM HAMMER/I5 FOOD #83113
STREET_NUMBER
3250
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
08240009
CURRENT_STATUS
01
SITE_LOCATION
3250 W HAMMER LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232224_3250 W HAMMER_1999-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
437
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page 7 <br /> 7. UNDER-DISPENSER CONTAINMENT (UDC) TESTING <br /> Test Method Developed By: ❑ UDC Manufacturer F] Industry Standard �X Professional Engineer <br /> 0 Other (Specify) <br /> Test Method Used: ❑ Pressure F-1 Vacuum X❑ Hydrostatic <br /> Other (Spec) <br /> Test Equipment Used: vplt Equipment Resolution: <br /> UDC# 1/2 UDC# 3/4 UDC# 5/6 UDC# 7/8 <br /> UDC Manufacturer: bravo bravo bravo bravo <br /> UDC Material: metal metal metal metal <br /> UDC Depth: 1011 1011 1011 1011 <br /> Height from UDC Top to Top of 0 0 0 0 <br /> Highest Piping Pentration: <br /> Height from UDCTop to Lowest 0 0 0 10 <br /> Electrical Pentration: <br /> Condition of UDC prior to testing: good good good good <br /> Portion of UDC Tested: 1 211 211 211 211 <br /> Does turbine shut down when <br /> sump sensor detects liquid(both X]Yes❑No[:]N MYes F—]No[::]N Yes❑NoE:]N E Yes❑No[]N <br /> product and water)?* <br /> Turbine shutdown response time: 2-5sec 2-5sec 2-5sec 2-5 s e c <br /> Is system programmed for fail-safe ❑ � ❑ X ❑ ❑ ❑ <br /> shutdown?* Yes X N N Yes N N Yes X N N Yes ENoaA <br /> Was fail-safe verified to be ❑ ❑ ❑ ❑ ❑ <br /> operational?* Yes X N N Yes X N N Yes X N N Yes X No <br /> Wait time between applying <br /> pressure/vacuum/water and starting 5min 5min 5min 5min <br /> test: <br /> Test Start Time: 10:19 9:56 11:2 2 11:44 <br /> Initial Reading(R1): 7.032 4.657 12 .682 9.763 <br /> Test End Time: 10:34 10:11 11:37 11:59 <br /> Final Reading(RF): 7.032 4.638 12 .682 9.763 <br /> Test Duration: 15min 15min 15min 15min <br /> Change inReading(RF-R1 ): .000gph 001gph .000gph .000gph <br /> Pass/Fail Threshold or Criteria: .05gph .05gph .05gph .05gph <br /> EffiffieffiffiRm EMEM ", I ONE= <br /> Was sensor removed for testing? YesI" No❑NA❑YesL.L j Yes X N NA Yes ENoaA <br /> Was sensor properly replaced and �verifed functional after testing? ❑Ye XN NAF11 1 _1 YesMNc1_1 NA ❑Ye�N�NA[]Yes <br /> Yes X Nq: <br /> Comments- (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> 1 If the entire depth of the UDC is not tested,specify how much was tested.If the answer to a�of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />