Laserfiche WebLink
e j <br /> Alltech Petro Inc. - <br /> 17759 Buttercup Circle, Sonora, CA 95370 <br /> Phone: 209-532-7320; Fax: 209-533-2650 <br /> California Contractor 623541 A-Haz <br /> Mike@AlltechPetro.com I d <br /> MONITORING SYSTEM CERTIFICATION <br /> A. General Information <br /> Facility Name: Hammer I-5 Arco Date of Testing/Servicing: August 9,2007 <br /> Facility Address:3250 Hammer Lane,Stockton CA 95209 <br /> Facility Contact Person: Wes Parkinson Contact Phone No.: 474-9125 <br /> Regulatory agency: San Joaquin Health;Inspector: Michelle Henry; Phone: 468-9847;Fax 468-3433 <br /> Make/Model of Monitoring System: Veeder-Root TLS-350 <br /> This test report is a:®Final Report(Facility was observed to be in Compliance)or a❑Preliminary Report(Unresolved Issues Exist) <br /> B. Inventoa of E ui ment Tested/Certified: <br /> Tank ID:Regular Master Tank ID: Regular Skave <br /> ®In-Tank Gauging Probe. Model:Mag I ®In-Tank Gauging Probe. Model: Mag 1 <br /> ®Annular Space or Vault Sensor. Model:794390-409 ®Annular Space or Vault Sensor. Model:794390-409 <br /> ®Piping Sump Sensor(s). Model:794380-208 ®Piping Sump Sensor(s). Model:794380-208 <br /> ❑Fill Sump Sensor(s). Model:NONE ❑Fill Sump Sensor(s). Model:NONE <br /> ®Mechanical Line Leak Detector. Model:Red Jacket ❑Mechanical Line Leak Detector. Model: Shared <br /> ❑Electronic Line Leak Detector. Model:NONE ❑Electronic Line Leak Detector. Model:NONE <br /> ®Tank Overfill/High-Level Sensor. Model:Drop Tube ®Tank Overfill/High-Level Sensor. Model:Drop Tube <br /> ®Fills ill buckets tested ®Pass ❑Fail ®Fills ill buckets tested ®Pass ❑Fail <br /> Tank ID:Premium Tank ID: <br /> ®In-Tank Gauging Probe. Model:Mag I ❑In-Tank Gauging Probe. Model: <br /> ®Annular Space or Vault Sensor. Model: 794390-409 ❑Annular Space or Vault Sensor. Model: <br /> ®Piping Sump Sensor(s). Model: 794380-208 ❑Piping Sump Sensor(s). Model: <br /> ❑Fill Sump Sensor(s). Model:NONE ❑Fill Sump Sensor(s). Model: <br /> ®Mechanical Line Leak Detector. Model:FE Petro ❑Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector. Model:NONE ❑Electronic Line Leak Detector. Model: <br /> ®Tank Overfill/High-Level Sensor. Model:Drop Tube ❑Tank Overfill/High-Level Sensor. Model: <br /> ®Fills ill buckets tested ®Pass []Fail ❑Fills ill buckets tested ❑Pass ❑Fail <br /> Vapor Condensate Sump: 1&2 ®Dry❑Water❑Product Piping Transition Sump:3&4 ®Dry❑Water❑Product <br /> ® Sensor(s). Model:794380-208 ® Sensor(s). Model:794380-208 <br /> Dispenser ID: 1&2® Sump:®Dry ❑Water❑Product Dispenser ID:3&4®Sump: ®Dry❑Water❑Product <br /> ❑Dispenser Containment Sensor(s). Model:Bravo Box ❑Dispenser Containment Sensor(s). Model:Bravo Box <br /> ®Shear Valve(s) (Functional test) ®Shear Valve(s) (Functional test) <br /> ® <br /> Dispenser Containment Floats and Chains. ®Disenser Containment Float(s)and Chains . <br /> Dispenser ID:5&6❑Sump:❑Dry❑Water❑Product Dispenser ID:7&8❑Sump:❑Dry❑Water❑Product <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ❑Shear Valve(s) (Functional test) ❑Shear Valve(s) (Functional test) <br /> ❑Dispenser Containment Floats and Chain(s). ❑Dispenser Containment Floats and Chain(s). <br /> C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the <br /> manufacturers' guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this <br /> information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such <br /> reports,I have also attached a copy of the report;(check all that apply): ®System set-up ®Alarm history report <br /> Technician: Mike Dotten,California Contractor License.No.: 623541 <br /> Certification: Veeder-Root:341-32-6743; Level 4. ICC UST Technician#5259412-UT <br />