My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3250
>
2300 - Underground Storage Tank Program
>
PR0232224
>
COMPLIANCE INFO_2011-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2021 10:16:11 AM
Creation date
6/3/2020 9:56:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2018
RECORD_ID
PR0232224
PE
2361
FACILITY_ID
FA0001877
FACILITY_NAME
AM PM HAMMER/I5 FOOD #83113
STREET_NUMBER
3250
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
08240009
CURRENT_STATUS
01
SITE_LOCATION
3250 W HAMMER LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232224_3250 W HAMMER_2011-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
452
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sjgov.or /q ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> AN. Pfv1 i-i%MME€d115 FOOD 483113 W , STocl,vTot1 >� � N:� y�•�. �%�s; ,.,.. � iutay 25, 2017 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions. <br /> Maintenance and monitoring records for tho iast three years were not found on site. Secondary containment testing <br /> report for testing completed on 517/15 and the monitoring system certification(MSC)testing report for 2014 were not <br /> available during the inspection. These records sh?!r be maintained on site for at least three years. Monitoring <br /> records include: (1)date and time of all monitoring or sampling, (2) monitoring equipment calibration Pnd <br /> maintenance records;(3) results of any visual observations; (4)results of sample analysis performed a lab or in the <br /> field; (5)logs of all readings of gauges or other monitoring equipment, grou:<d eater elevations, or oth"or test result_. <br /> (6) results of inventory readings and reconciliations. A copy of the seccnciary containment testing report and 2011 <br /> MSC report were made available during the inspection. <br /> This was corrected Oil site. <br /> This is a repeat violation. Class 11. <br /> rte° CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator failed to document all the alarms frons:h': attached alarm history on the July 25,2016 <br /> designated operator monthly inspection report and failed to check that they were responded to appropriately. The <br /> missing alarms include: L8: South Piping Sump Low Liquid Alarm on July 1, 2016. The designated operator <br /> addressed the 1_6:"92" sump STP sump fuel alarms on the designated operator monthly inspection reports for: <br /> 7/25/16. 10/24/16, 11122/16, 1/25117, 2124/17, 3128/17 and 4124/17 : however, the designated operator failed to <br /> check the box"Yes"for Iters 4 "Has each alarm for the previous month been responded to appropriately?" Instead <br /> the designated operator checked"NA". <br /> During the monthly inspection, the designated operator shallreview the alarm history for the I;revioas month, checE; <br /> that each alarm was documented and responded to appropriately, and attach a copy of the alarm history with <br /> documentation taken in response to any alarms to the monthly report. Ensure that designated operators performing <br /> monthly inspections at this facility are including all of the required information on the reports. <br /> The designated operator failed to check and note the correct test dates for the secondary containment testing on <br /> the June 2016 through April 2017 designated operator monthly inspection report. Instead of entering 5/7/2015, the <br /> designated operator entered 5/7/2016. During the monthly inspection, the designated operator shall check that all <br /> required testing and rnaintc:..rrce for the UST system have been conipleted and document the dates they were <br /> done. Ensure that desigrtZ'e-!operators performing monthly inspections at this facility are including all of the <br /> required information on the reports. <br /> ill,is a repeat violation, Class 11. <br /> FA0001877 PRO232224 SCO01 05/25/2017 <br /> EHD 23-01 Rev,09122/16 Page 4 of 6 Underground Storage Tank Program OR <br />
The URL can be used to link to this page
Your browser does not support the video tag.