My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3250
>
2300 - Underground Storage Tank Program
>
PR0232224
>
COMPLIANCE INFO_2011-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2021 10:16:11 AM
Creation date
6/3/2020 9:56:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2018
RECORD_ID
PR0232224
PE
2361
FACILITY_ID
FA0001877
FACILITY_NAME
AM PM HAMMER/I5 FOOD #83113
STREET_NUMBER
3250
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
08240009
CURRENT_STATUS
01
SITE_LOCATION
3250 W HAMMER LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232224_3250 W HAMMER_2011-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
452
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A11teChPetr'B- or <br />Compliance without Compromise <br />A. General Information <br />P.O. Box 4208 <br />Sonora CA 95370 <br />Ca: 623541 A-Haz <br />Phone: 209-532-7320 <br />Fax: 209-533-2650 <br />mail @a I (tech pet ro. co m <br />www.alitechpetro.com <br />Facility Name: Hammer 1-5 Arco Date of Testing/Servicing: 05/26/16 <br />Facility Address: 3250 Hammer Lane, Stockton CA 95209 <br />Facility Contact Person: Wes Parkinson Contact Phone No.: 209-474-9125 <br />Regulatory agency: San Joaquin Health; Inspector: Stacy Rivera; Phone: 209-468-9847; Fax 209-468-3433 <br />Make/Model of Monitoring System: Veeder- Root TLS -350 <br />B. Inventory of Equipment Tested/Certified: <br />Tank ID: 87A <br />Tank ID: 87B <br />®In -Tank Gauging Probe. Model: Mag 1 <br />®In -Tank Gauging Probe. Model: Mag 1 <br />®Annular Space or Vault Sensor. Model: 794390-409 <br />®Annular Space or Vault Sensor. Model: 794390-409 <br />®Piping Sump Sensor(s). Model: 794380-208 <br />®Piping Sump Sensor(s). Model: 794380-208 <br />❑Fill Sump Sensor(s). Model: NONE <br />El Fill Sump Sensor(s). Model: NONE <br />®Mechanical Line Leak Detector. Model: Red Jacket <br />❑Mechanical Line Leak Detector. Model: Shared <br />❑Electronic Line Leak Detector. Model: NONE <br />❑Electronic Line Leak Detector. Model: NONE <br />®Tank Overfill / High -Level Sensor. Model: Drop Tube <br />®Tank Overfill/ High -Level Sensor. Model: Drop Tube <br />® Fills ill buckets tested ®Pass ❑Fail <br />® Fills ill buckets tested ®Pass ❑Fail <br />Tank ID: 91 <br />Tank ID: <br />®In -Tank Gauging Probe. Model: Mag 1 <br />El In -Tank Gauging Probe. Model: <br />®Annular Space or Vault Sensor. Model: 794390-409 <br />❑Annular Space or Vault Sensor. Model: <br />®Piping Sump Sensor(s). Model: 794380-208 <br />❑Piping Sump Sensor(s). Model: <br />❑Fill Sump Sensor(s). Model: NONE <br />❑Fill Sump Sensor(s). Model: <br />®Mechanical Line Leak Detector. Model: FE Petro <br />F1 Mechanical Line Leak Detector. Model: <br />❑Electronic Line Leak Detector. Model: NONE <br />El Electronic Line Leak Detector. Model: <br />®Tank Overfill / High -Level Sensor. Model: Drop Tube <br />❑Tank Overfill / High -Level Sensor. Model: <br />® Fillspill buckets tested ®Pass [-]Fail <br />❑ ❑Pass ❑Fail <br />Vapor Condensate Sump: ®Dry ❑Water ❑Product <br />Piping Transition Sump: ®Dry ❑Water ❑Product <br />® Sensor(s). Model: 794380-208 <br />® Sensor(s). Model: 794380-208 <br />® Vapor Pot Sensor(s). Model: 794380-420 <br />Dispenser ID: 1&2 ® Sump: ®Dry ❑Water ❑Product <br />Dispenser ID: 3&4 ❑ Sump: ❑Dry [-]water ❑Product <br />®Dispenser Containment Model: Float and Chain <br />Dispenser Containment Model: Float and Chain <br />®Shear Valve(s) (Functional test) <br />®Shear Valve(s) (Functional test) <br />®Dispenser Containment Float(s) and Chain(s). <br />Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 5&6 ® Sump: ®Dry ❑Water ❑Product <br />Dispenser ID: 7&8 ® Sump: ®Dry ❑Water ❑Product <br />®Dispenser Containment Model: Float and Chain <br />®Dispenser Containment Model: Float and Chain <br />®Shear Valves) (Functional test) <br />®Shear Valve(s) (Functional test) <br />®Dispenser Containment Float(s) and Chain(s). <br />®Dispenser Containment Float(s) and Chain(s). <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the <br />manufacturers' guidelines. Attached to this Certification is information (e.g. manufacturers' checklists)' necessary to verify that this <br />information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such <br />reports, I have also attached a copy of the report; (check a// that app/yt ®System set-up ® Alarm history report <br />Signature of Technician: Date: 05/26/16 <br />Certification: ICC UST Technician # 8146912 -UT <br />Veeder Root # 836878 Level 4 ISD <br />
The URL can be used to link to this page
Your browser does not support the video tag.