My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3250
>
2300 - Underground Storage Tank Program
>
PR0232224
>
COMPLIANCE INFO_2011-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2021 10:16:11 AM
Creation date
6/3/2020 9:56:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2018
RECORD_ID
PR0232224
PE
2361
FACILITY_ID
FA0001877
FACILITY_NAME
AM PM HAMMER/I5 FOOD #83113
STREET_NUMBER
3250
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
08240009
CURRENT_STATUS
01
SITE_LOCATION
3250 W HAMMER LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232224_3250 W HAMMER_2011-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
452
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IFIED PROGRAM CONSOLIDATED FORM <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN (Page 2 of 2) <br /> 77 <br /> /trx � 3 a7-7777 <br /> 1. UDC MONITORING IS PERFORMED USING THE FOLLOWING METHOD 490-54e <br /> '❑ 1.CONTINUOUS ELECTRONIC MONITORING ®2.FLOAT AND CHAIN ASSEMBLY ❑ 3.ELECTRONIC STAND-ALONE 490-54b <br /> ❑4.NO DISPENSERS E199.OTHER(Specify): <br /> PANEL MANUFACTURER: 490-55 MODEL#: 490-56. <br /> LEAK SENSOR MANUFACTURER:Bravo Boa 490-57 i MODEL#(S):Unknown 490-58 <br /> DETECTION OF A LEAK INTO THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS ❑ -YES ®b.NO 49-59 <br /> UDC LEAK ALARM TRIGGERS AUTOMATIC PUMP SHUTDOWN ❑ a.YES ®b.NO 490-60 <br /> FAILURE/DISCONNECTION OF UDC MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a YES ®b.NO 490-6] <br /> UDC MONITORING STOPS THE FLOW OF PRODUCT AT THE DISPENSER. ® a.YES ❑b.NO 490-62 <br /> 2.UDC CONSTRUCTION IS ®1.SINGLE-WALLED ❑2.DOUBLE-WALLED 490-63 <br /> IF DOUBLE WALLED: 490-64a <br /> UDC INTERSTITIAL SPACE IS MONITORED BY: ❑ L LIQUID [12.PRESSURE [13.VACUUM <br /> ------------ <br /> A LEAK WITHIN THE SECONDARY CONTAINMENT OF THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS ❑a YES ❑b NO <br /> _ ., <br /> k 490-64b <br /> ❑ 1. ELD TESTING: THIS FACILITY HAS BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT ENHANCEDago ss. <br /> LEAK DETECTION(ELD MUST BE PERFORMED. PERIODIC ELD IS PERFORMED EVERY 36 MONTHS AS REQUIRED.(23 CCR2644 <br /> ®2.SECONDARY CONTAINMENT COMPONENTS ARE TESTED EVERY 36 MONTHS. 490-66 <br /> ®3.SPILL BUCKETS ARE TESTED ANNUALLY. <br /> 490-67 <br /> The following monitoring/maintenance records are kept for this facility: <br /> ®Alar logs ago-baa ❑Visual Inspection Records 49"sb ❑Tank integrity testing results 490-68. <br /> ❑SIR testing results(and supporting documentation records). 4ga68d ❑ Tank gauging results(and supporting documentation records). 4go-6se <br /> ❑ATG Testing results(and supporting documentation records).4go-68f ❑ Corrosion Protection 60-day logs 490-654 <br /> ❑Equipment maintenance and calibration records. 490-68h <br /> ®Personnel with UST monitoring responsibilities are familiar with all of the following documents relevant to their job duties. 4go-694 <br /> REFERENCE DOCUMENTS MAINTAINED AT FACILITY(Check all that apply) <br /> ® THIS UNDERGROUND STORAGE TANK MONITORING PLAN(Required)490-69b <br /> ® OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT(Required)4go-69c <br /> ® CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS 490-69d <br /> ® CALIFORNIA UNDERGROUND STORAGE TANK LAW 490.6% <br /> ® STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR TANK OWNERS - MANUAL AND <br /> STATISTICAL INVENTORY RECONCILIATION"490-69f <br /> ® SWRCB PUBLICATION:"UNDERSTANDING AUTOMATIC TANK GAUGING SYSTEMS"490-695 <br /> ❑ OTHER(Specify):M6gh,M6gi <br /> ®This facility has a"Designated UST Operator"who has passed the California UST System Operator Exam administered by the International Code Council(ICC). <br /> The"Designated UST Operator"will train facility employees in the proper operation and maintenance of the UST systems annually,and within 30 days of hire.This <br /> training will include,but is not limited to,the following: <br /> ➢ Operation of the UST systems in a manner consistent with the facility's best management practices <br /> ➢ The facility employee's role with regard to the monitoring equipment as specified in this UST Monitoring Plan <br /> ➢ The facility employee's role with regard to spills and overfills as specified in the UST Response Plan <br /> ➢ Names of contact person(s)for emergencies and monitoring alarms.490-70 <br /> Provide Overfillprotection <br /> comments here or indicate now man es with additional information � �` <br /> Y P� � � ration on specific monitoring procedures are attached to this plan.aga7t <br /> p on is provided by a flapper assembly in the drop tubes that restrict flow when the liquid level reaches 95%of the UST's capacity. <br /> - . <br /> The UST Owner/Operator is responsible for ensuring that:1)the daily/routine UST monitoring activities and maintenance of UST leak detection equipment covered by <br /> this plan occurs,2)all conditions that indicate a possible release are investigated,and 3)all monitoring records are maintained properly. <br /> The following person(s)are responsible for performing the monitoring and equipment maintenance: <br /> NAME o 48-72 TITLE <br /> NAME 44474 TITLE 440-73 <br /> 49-75 <br /> The Designated Operator shall perform a monthly visual inspection of the facility, provide a report to the owner/operator, and inform the owner/operator of any <br /> conditions that need follow-up action. <br /> CERTIFICATION.I certify that a information provided hereinis true and accurate to thebest of my knowledge. <br /> _ APPL�T SI A P 490-76 DATE: agar <br /> ator 3.Autbo' R o e f <br /> APPLICAN AME(print): 4W78 APPLICANT TIT 490-79 <br /> UPCF UST-D(12/2007)3/4 <br />