My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3250
>
2300 - Underground Storage Tank Program
>
PR0232224
>
COMPLIANCE INFO_2011-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2021 10:16:11 AM
Creation date
6/3/2020 9:56:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2018
RECORD_ID
PR0232224
PE
2361
FACILITY_ID
FA0001877
FACILITY_NAME
AM PM HAMMER/I5 FOOD #83113
STREET_NUMBER
3250
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
08240009
CURRENT_STATUS
01
SITE_LOCATION
3250 W HAMMER LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232224_3250 W HAMMER_2011-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
452
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ox 4208 <br /> RECEIVES P.O. A95370 <br /> ' Sonora CA 95370 <br /> AlitechPetr - <br /> Ca:623541 -7320 <br /> JUL��"L V z 2U�U Phone:209-532-7320 <br /> Compliance without Compromise ���Tqq Fax:209-533-2650 <br /> LHEALTH mail@alltechpetro.com <br /> MONITORING SYSTEM CERTM �h <br /> V!CES www.alltechpetro.com <br /> A. General Information <br /> Facility Name: Hammer 1-5 Arco Date of Testing/Servicing: 05/07/15 <br /> Facility Address: 3250 Hammer Lane, Stockton CA 95209 <br /> Facility Contact Person: Wes Parkinson Contact Phone No.: 209-474-9125 <br /> Regulatory agency: San Joaquin Health; Inspector: Stacy Rivera; Phone: 209-468-9847; Fax 209-468-3433 <br /> Make/Model of Monitoring System: Veeder- Root TLS-350 <br /> B. Inventory of Equipment Tested/Certified: <br /> Tank ID: 87A Tank ID: 87B <br /> ®In-Tank Gauging Probe. Model: Mag 1 ®In-Tank Gauging Probe. Model: Mag 1 <br /> ®Annular Space or Vault Sensor. Model: 794390-409 ®Annular Space or Vault Sensor. Model: 794390-409 <br /> ®Piping Sump Sensor(s). Model: 794380-208 ®Piping Sump Sensor(s). Model: 794380-208 <br /> F-1 Fill Sump Sensor(s). Model: NONE ❑Fill Sump Sensor(s). Model: NONE <br /> ®Mechanical Line Leak Detector. Model: Red Jacket ®Mechanical Line Leak Detector. Model: Shared <br /> F-1 Electronic Line Leak Detector. Model: NONE F1 Electronic Line Leak Detector. Model: NONE <br /> ®Tank Overfill/High-Level Sensor. Model: Drop Tube ®Tank Overfill/High-Level Sensor. Model: Drop Tube <br /> ® Fillspill buckets tested ®Pass ❑Fail ® Fillspill buckets tested ®Pass ❑Fail <br /> Tank ID: 91 Tank ID: <br /> ®In-Tank Gauging Probe. Model: Mag 1 ❑In-Tank Gauging Probe. Model: <br /> ®Annular Space or Vault Sensor. Model: 794390-409 ❑Annular Space or Vault Sensor. Model: <br /> ®Piping Sump Sensor(s). Model: 794380-208 ❑Piping Sump Sensor(s). Model: <br /> ❑Fill Sump Sensor(s). Model: NONE ❑Fill Sump Sensor(s). Model: <br /> ®Mechanical Line Leak Detector. Model: FE Petro ❑Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector. Model: NONE ❑Electronic Line Leak Detector. Model: <br /> ®Tank Overfill/High-Level Sensor. Model: Drop Tube ❑Tank Overfill/High-Level Sensor. Model: <br /> ® Fillspill buckets tested ®Pass ❑Fail ❑ ❑Pass [—]Fail <br /> Vapor Condensate Sump: ®Dry❑Water❑Product Piping Transition Sump: ®Dry❑Water❑Product <br /> ® Sensor(s). Model: 794380-208 ® Sensor(s). Model: 794380-208 <br /> ® Vapor Pot Sensor(s). Model: 794380-420 <br /> Dispenser ID: 1&2 ® Sump: ®Dry❑Water❑Product Dispenser ID: 3&4® Sump: ®Dry❑Water❑Product <br /> ®Dispenser Containment Model: Float and Chain ®Dispenser Containment Model: Float and Chain <br /> ®Shear Valve(s) (Functional test) ®Shear Valve(s) (Functional test) <br /> ®Dispenser Containment Float(s)and Chain(s). ®Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5&6® Sump: ®Dry❑Water❑Product Dispenser ID: 7&8 ® Sump: ®Dry❑Water❑Product <br /> ®Dispenser Containment Model: Float and Chain ®Dispenser Containment Model: Float and Chain <br /> ®Shear Valve(s) (Functional test) ®Shear Valve(s) (Functional test) <br /> 01 ®Dispenser Containment Floats and Chain(s). ®Dis enser Containment Floats and Chain (s). <br /> C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the <br /> manufacturers' guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this <br /> information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such <br /> reports,I have also attached a copy of the report; (check a//that app/y}. ® System set-up ®Alarm history report <br /> Signature of Technician: Date: 05/07/15 <br /> Certification: ICC UST Technician # 8146912-UT <br /> Veeder Root # B36878 Level 4 ISD <br />
The URL can be used to link to this page
Your browser does not support the video tag.