Laserfiche WebLink
S A N A A Q U I N Environmental Health Department <br /> COUNTY <br /> _ , . <br /> Underground Storage Tank Program Inspection Report ; <br /> Facility Name: Facility Address: Date: <br /> AM PM HAMMER/15 FOOD#83113 3250 W HAMMER LN, STOCKTON May 24, 2018 <br /> SUMMARY-'OF VIOLATIONS <br /> (CLASS I,CLASS U or 0111 Notice to Comply] <br /> Item# Remarks <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report. <br /> An inspection was last done on 05/25/17 and an inspection report was issued identifying information to be submitted <br /> to bring this site into compliance. This information was required to be submitted by 6/24/17. This information has <br /> not been received resulting in a non-compliant status for this facility. An operator that receives an inspection report <br /> shall have 30 days to submit a written response that includes a statement documenting corrective actions taken or <br /> proposing corrective actions which will be taken. Ensure that a written response documenting corrective actions <br /> taken or proposed is submitted within 30 days of receiving an inspection report. <br /> Remaining violations include: <br /> 1) Failed to inform the EHD of designated operator identification or change within 30 days.A new designated <br /> operator(DO), Shawn Rodriguez, completed the DO monthly inspection reports from May 2016 through April 2017 <br /> and notification was not provided to the EHD within 30 days of the change.Any changes shall be reported to the <br /> EHD within 30 days. Immediately log into the California Environmental Reporting System(CERS)at <br /> http://cers.calepa.ca.gov and upload the notification identifying all the designated operators for this facility. <br /> 2) Designated operator employee training not performed or log not kept. <br /> The designated operator failed to list the"Hire Date"for Sally Moreno and there is no record of recent training for <br /> Wes Parkinson.The designated operator shall train facility employees for which he or she is responsible in the <br /> proper operation and maintenance of the UST system once every 12 months. The training shall include, but is not <br /> limited to: <br /> 1. Operation of the UST system in a manner consistent with the facility's best management practices <br /> 2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br /> 3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br /> 4. Name of the contact person(s)for emergencies and monitoring equipment alarms <br /> Ensure that employees have been trained by the designated operator, maintain the list on site, and submit a copy of <br /> the training records to the EHD. <br /> This is a repeat violation, Class 11. <br /> 209 CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> 1)The designated operator failed to document all the alarms from the attached alarm history on the 8/23/17 <br /> designated operator monthly inspection report and failed to check that they were responded to appropriately. The <br /> missing alarms include: an L6 91 STP sump fuel alarm occurring on 8/2/17. <br /> 2)The designated operator put the incorrect date on the July 25th, 2017 designated operator monthly inspection <br /> report as 7/25/19 and failed to attach a copy of the alarm history. <br /> During the monthly inspection,the designated operator shall review the alarm history for the previous month, check <br /> that each alarm was documented and responded to appropriately, and attach a copy of the alarm history with <br /> documentation taken in response to any alarms to the monthly report. Ensure that designated operators performing <br /> monthly inspections at this facility are including all of the required information on the reports. <br /> This is a repeat violation, Class 11. <br /> FA0001877 PR0232224 SCO01 05/24/2018 <br /> EHD 23-01 Rev.10/31/2017 Page 5 of 6 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />