My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005-2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1777
>
2300 - Underground Storage Tank Program
>
PR0232397
>
COMPLIANCE INFO_2005-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/14/2023 1:36:01 PM
Creation date
6/3/2020 9:56:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2010
RECORD_ID
PR0232397
PE
2361
FACILITY_ID
FA0003978
FACILITY_NAME
KAISER FOUNDATION - MANTECA
STREET_NUMBER
1777
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95337
APN
20018034
CURRENT_STATUS
01
SITE_LOCATION
1777 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232397_1777 W YOSEMITE_2005-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
465
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r <br /> 2098253893 ENGINEERING DEPT. 090 6 a.m. 09-10-2010 21 /21 <br /> M ring System Certification <br /> Site Address: 1777 W YOSEMITE AVE Date of Testing/Service: 08/13/2010 <br /> In-Tank Gauging/SIR Equipment <br /> ❑ Check this box if tank gauging is used only for inventory control. <br /> ® Check this box if no tank gauging or SIR equipment is installed. <br /> Check this box if no tank gauging or SIR equipment is instphod. <br /> This section must be completed if in-tank gauging equipment;is used to perform leak detection monitoring. <br /> Complete the following checklist: <br /> ❑Yes ❑No* Has all input wiring been inspected for proper entry and termination,including testing for ground faults? <br /> ❑Yes ❑No* Were all tank gauging probes visually inspected for damage and residue buildup? <br /> ❑Yes ❑No* Was accuracy of syst'm product level readings tested? <br /> ❑Yes ❑No` Was accuracy of sys em water level readings test ? <br /> Yes [:]No* were all probes reinstalled properly? <br /> ®Yes ❑No I Were all items on the equipment manufacturers'maintenance checklist completed? <br /> * below,describe how and when these deficiencies were or will be corrected. <br /> In the Section Hf <br /> G. Line Leak Detectors(LLD) : x❑ Check this box if LLDs are not installed. <br /> Complete the following checklist:;f <br /> For egdipment start-up or annual equipment certification,was a leak simulated to verify LLD performance? <br /> ❑Yes ❑No° E]N/A (Check all that apply)Simulated leak rate: ❑ 3 g.p.hE]0.1 g.p.h ❑0.2 g.p.h <br /> Yes ❑No* Were all LLDs confirmed operational and accurate within regulatory requirements? <br /> C-'Yes [:]NO- Was the testing apparatus pro eriy calibrated? <br /> _j Yes []No*l❑N/A For mechanical LLDs,does the°LLD restrict product flow if it detects a leak? <br /> ❑Yes ❑No° ❑N/A For electronic LLDs,does the turbine automatically shut off if the LLD detects a leak? <br /> ❑Yes ❑No* ❑N/A For electronic LLDs,does thekurbine automatically shut off if any portion of the monitoring system is disabled or disconnected? <br /> ❑Yes ❑No• ❑N/A For electronic LLDs,does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a test? <br /> ®Yes ❑No* ❑N/A For electronic LLDs,:have all accessible wiring connections been visually inspected? <br /> ❑Yes ❑No* Were all items on the equipment manufacturers'maintenance checklist completed? <br /> *In the Section H,below,describe how and when these deficiencies were or will be corrected. <br /> H. Comments: <br /> NO LD'S AND TANK GAUGE. <br /> e <br /> Page 3 of 3 Based on CA form dated 03/08 <br />
The URL can be used to link to this page
Your browser does not support the video tag.