ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2017-2018
RECORD_ID
PR0232397
PE
2361
FACILITY_ID
FA0003978
FACILITY_NAME
KAISER FOUNDATION - MANTECA
STREET_NUMBER
1777
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95337
APN
20018034
CURRENT_STATUS
01
SITE_LOCATION
1777 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\Y\YOSEMITE\1777\PR0232397\RETROFIT PLAN 2017.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
310
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Outdoor Installations <br />When installed outdoors, the DoubleTrac piping must be adequately protected from puncture, shear, crush or other <br />physical damage threats, including possible damage from: <br />• vehicular or pedestrian traffic, corrosion, <br />• twisting, bending, kinking, chafing, or other excessive or prolonged movement of the piping, <br />• construction and excavation, <br />When installed along the side of a structure in an exposed condition, the DoubleTrac piping shall be installed in a location <br />which will not subject the piping to mechanical damage. NOTE: For support and protection, OmegaFlex recommends <br />that outside runs along the side of a building be clipped securely to the wall or other structural component every six feet. <br />Typical supports are Unistrut conduit hangers, "U" bolts, PVC pipe couplers, or Hosebuns. <br />TYPICAL <br />Marina Installations <br />{ <br />Fixed Dock <br />When installing DoubleTrac® on a fixed dock, the piping may be run along the side or underneath it. In either case, the <br />routing must be such that in cannot be damaged, crush, kinked during normal use of the dock. The piping must be <br />supported evenly along the entire run; supports are required every six feet. Typical supports are Unistrut conduit hangers, <br />"U" bolts, PVC pipe couplers, or Hosebuns. <br />Floating Dock <br />DoubleTrac° should not be installed on the walkway from the shore to the dock. The constant flexing due to tide changes <br />will cause fatigue and possible failure of the primary piping. The dock to shore connection should be an approved flexible <br />connector. DoubleTrac® piping can be installed along the length of the floating dock portion. The routing must be such <br />that in cannot be damaged, crush, kinked during normal use of the dock. The piping must be supported evenly along <br />the entire run; supports are required every six feet. Typical supports are Unistrut conduit hangers, "U" bolts, PVC pipe <br />couplers, or Hosebuns. <br />DoubleTrac® piping is not an approved flex connector. Please contact OmegaFlex Engineering Department for flexible <br />double contained dock connectors at 1-800-355-1039. <br />Routine Maintenance and Visual Inspections <br />It is recommended that a visual inspection of all components as well as the inside of all containment sumps be <br />completed at least once per month. Typical monthly inspections include, but are not limited to: <br />• visual inspection of piping: no visible damage to the outer jacket such as cracks, crushing, kinking, or puncture <br />• visual inspection of all mounting hardware: all hardware must be intact and securely mounted in the original location <br />• visual inspection of DoubleTrac fittings: no visible damage to fittings, no sign of leakage, any vent/test port fittings or <br />bypass hoses should be show no sign of crushing, kinking, or puncture. <br />Fuel leaks collected in containment sumps must be reported immediately and investigated by the site owner. If leakage <br />or damage to the piping system is observed or suspected, OmegaFlex must be notified immediately. All sumps must be <br />kept free of fuel, water and debris. When changing fuel filters at the dispenser, make sure any spilled product is cleaned <br />out of the bottom of the dispenser sump to prevent possible fire hazard. <br />Contact Information <br />OmegaFlex Inc. can be contacted if there are any questions concerning the installation, maintenance or repair of <br />DoubleTrac® flexible piping system. Please contact OmegaFlex customer service and 1-800-355-1035 or on the web at <br />www.omegaflex.com or www.doubletrac.net. <br />Page 10 <br />