Laserfiche WebLink
wscure <br /> Rocs.UQ+ grw.d.Pip q•RA 01 <br /> SITE— <br /> Kaiser Manteca <br /> 1777 W.YosemPPte <br /> Manteca,CA 95337 <br /> Contractor— <br /> Lescure Company,Inc. <br /> 2301 Arnold Industrial Way,Suite C <br /> Concord,CA.94520 <br /> Purpose of Lancer— <br /> Response to Notice of Violation from San Joaquin County Health Department CCR 2712(b)Failure to <br /> maintain monitoring,maintenance and follow up salon records. <br /> To whom It may concern, <br /> It was brought to Lescure Company,Inc.attention through Kaiser Permanente channels that a violation <br /> was given to the facility stating that compliance was not followed by our company during the filtering <br /> and treatment of the product Inside of the UST.in my service report I had stated what work was done <br /> and that 3 alarms had gone off at the ATG.I also had noted what the particular action was that caused <br /> the alarm in the two instances.Two from disconnecting the cord cap off the probe to remove It from the <br /> UST and the other from circulating the fuel. <br /> In the violation,it was stated or suggested that Lescure Company,Inc,reprogrammed the ATG to <br /> perform the work,which is not the case.A"PROBE OUT"Is one of a few alarms that is able to be <br /> displayed on the ATG screen and Alarm History.The ATG can also display"SYSTEM DATA WARNING"as <br /> per the Veeder•Root Manual No 576013.939 and No 576013.610.The Initial alarm carne up as"Probe <br /> Out"at 9:07am when the cord cap was removed from the probe.We then silenced the alarm by <br /> pressing"REO"Alarm button at the same time 9:07am.When depressing this button the ATG goes from <br /> an alarm condition to a"SYSTEM DATA WARNING'because you acknowledged the alarm by pressing <br /> the"RED"Alarm button.The warning stays In effect until the situation Is corrected.This was done at the <br /> end of the day as my service report states that was turned over to the owner during that week. <br /> On aside It would not be a normal Industry standard and go into the ATG and Just randomly change the <br /> recorded"SET UP",it Is also against Lescure Company,Inc.Standards.Our San Joaquin Hazmat Permit is <br /> the only paperwork we have at the moment to change the"SET UP'to add two leak sensors per the <br /> permit, I would like to phrase again that no one from Lescure Company,Inc or Dynamic Solutions <br /> 2301 Arnold Industrial Way,Sulte C•Concord,CA.94520 <br /> Phone(925)283-2528 fax(925)283-1630 <br />