Laserfiche WebLink
A1116 Amk�. <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209)468-3433 Web:www.sjgov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> KAISER FOUNDATION-MANTECA 1777 W YOSEMITE AVE MANTECA June 27 2018 <br /> K -SUMMARY`OF VIOLATIONS <br /> {CLASS 1,CLASS II,or MINOR-Notice to Comply) <br /> v <br /> Item # Remarks <br /> 201 CCR 2712(b) Failure to maintain monitoring, maintenance, and follow up action records. <br /> Maintenance and monitoring records for the last three years were not found on site. <br /> -A setup data warning occurred on the T2 overfill probe on 5/9/18. The maintenance record found on site was dated <br /> 5/17/18 and was issued by Holt of CA. According to Mr. Sam Corbin, the alarm was caused by work done by Quality <br /> Fuel Services. No work order was found from Quality Fuel Services. Reprogramming of the monitoring panel must be <br /> conducted by a properly certified technician. Reprogramming of the monitoring panel must be conducted by a <br /> properly certified technician. <br /> -A setup data warning occurred on the T2 overfill probe on 11/30/17. The maintenance record found on site stated the <br /> alarm was caused by removing the probe. Removal of the probe would cause a 'probe out'alarm. The alarm log next <br /> to the monitoring panel stated the alarm was caused by fuel cleaning. Reprogramming of the monitoring panel must <br /> be conducted by a properly certified technician. <br /> These records shall be maintained on site for at least three years. Monitoring records include: (1) date and time of all <br /> monitoring or sampling; (2) monitoring equipment calibration and maintenance records; (3) results of any visual <br /> observations; (4) results of sample analysis performed a lab or in the field; (5) logs of all readings of gauges or other <br /> monitoring equipment, ground water elevations, or other test results; (6) results of inventory readings and <br /> reconciliations. Immediately locate and maintain all maintenance and monitoring records for the last three years on <br /> site and submit copies to the EHD. <br /> This is a minor violation. <br /> 320 CCR 2635(b)(2) Overfill prevention system not present or failed to meet overfill requirements. <br /> The ATG used as the overfill prevention system is not currently functional on the diesel UST. The alarm sounded, but <br /> the light did was not functional. The technician replaced the light bulb and the overfill was verified as functional while <br /> on site. <br /> This was corrected on site. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by July 27, 2018. <br /> Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br /> applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br /> Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br /> Documents provided: Return to Compliance Certification form, schedule of free CUPA classes <br /> FA0003978 PR0232397 SCO01 06/27/2018 <br /> EHD 23-01 Rev.09/22/16 Page 4 of 5 Underground Storage Tank Program OIR <br />