My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2004-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3434
>
2300 - Underground Storage Tank Program
>
PR0232398
>
COMPLIANCE INFO_2004-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2023 10:56:57 AM
Creation date
6/3/2020 9:57:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004-2015
RECORD_ID
PR0232398
PE
2361
FACILITY_ID
FA0003681
FACILITY_NAME
STOCKTON AUTO CENTER CAR WASH
STREET_NUMBER
3434
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95212
APN
12802011
CURRENT_STATUS
01
SITE_LOCATION
3434 E HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232398_3434 E HAMMER_2004-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
579
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
V ty <br />..vc. Lu," <br />SAN JOAQUIN COUNTY <br />W: X <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, CA 95202-3029 <br />0 mechanical Model: <br />Telephone: (209) 468-3420 Fax. (209) 468-3433 Web: www.sigov.org/ehd <br />0 electronic Serial #: <br />UNDERGROUND <br />STORAGE TANK (UST) PROGRAM SERVICE REQUEST INSPECTION REPORT <br />Facility Name: Inspection Date: <br />I <br />Facility Address: SerAceRequest #: <br />Onsite Service Technician's Name: ICC Service Technician/installer Exp. Date: Manufacturer Training: <br />I--.- )<.- <br />1e— -7111 <br />SERVICE <br />Leak detector <br />El <br />0 mechanical Model: <br />0 electronic Serial #: <br />0 line test programmed <br />El <br />Leak detector <br />0 <br />0 mechanical Model: <br />El electronic Serial #: <br />El <br />0 line test programmed <br />Leak detector <br />E] <br />0 mechanical Model: <br />El <br />El electronic Serial #: <br />0 line test programmed <br />sensor <br />❑ <br />0 positive shutdown Model: <br />0 fail safe Serial #: <br />❑ <br />0 NA <br />sensor <br />❑ <br />0 positive shutdown Model: <br />El <br />E] fail safe Serial #: <br />El <br />El NA <br />sensor <br />❑ <br />0 positive shutdown Model: <br />• fail safe Serial #: <br />• NA <br />0 <br />Drop tube with mechanical overfill at 95% <br />❑ <br />Drop tube with mechanical overfill at 95% <br />El <br />Overfill prevention (see LG letter 150-1) <br />SERVICE <br />Spill bucket 0 minimum 5 gallon <br />El <br />El 1 hour hydrostatic 0 Incon TS -STS <br />El Caldwell System 0 Other <br />Spill bucket 0 minimum 5 gallon <br />El <br />0 1 hour hydrostatic 0 Incon TS -STS <br />El Caldwell System 0 Other <br />Spill bucket 0 minimum 5 gallon <br />El <br />0 1 hour hydrostatic 0 Incon TS -STS <br />0 Caldwell System 0 Other <br />Primary piping testing at: <br />El <br />psi <br />minutes <br />Secondary containment testing for: <br />UDC(s) Piping <br />Sump(s) UST(s) <br />❑ <br />Testing for the above components are next due by: <br />Note: Please be aware that 2* containment components are required to be tested upon <br />installation, 6 months after, and every 36 months thereafter. <br />Cold start of monitoring panel <br />El <br />Corrosion protection <br />El <br />Other: see below <br />EHD 23-04 <br />Rev 11/17//08 <br />UST SERVICE REQUEST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.