My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2004-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3434
>
2300 - Underground Storage Tank Program
>
PR0232398
>
COMPLIANCE INFO_2004-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2023 10:56:57 AM
Creation date
6/3/2020 9:57:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004-2015
RECORD_ID
PR0232398
PE
2361
FACILITY_ID
FA0003681
FACILITY_NAME
STOCKTON AUTO CENTER CAR WASH
STREET_NUMBER
3434
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95212
APN
12802011
CURRENT_STATUS
01
SITE_LOCATION
3434 E HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232398_3434 E HAMMER_2004-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
579
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DS -8000 series adhesives are UL <br />Listed for use with RED THREAD IIA <br />pipe and RED THREAD 11 fittings or <br />RED THREAD II secondary con- <br />tainment fittings for petroleum <br />products, alcohols, and alcohol - <br />gasoline mixtures. When joining <br />secondary containment fittings, a <br />special filler, available from Smith <br />Fiberglass Products, must be added <br />to the adhesive. All joints — both <br />product and secondary containment <br />pipe -to -pipe and pipe -to -fittings <br />— must be heat -cured using electric <br />heating collars or chemical heat <br />packs from Smith Fiberglass Products. <br />For petroleum products only, DS - <br />7000 series adhesives can be used. <br />You must add a special filler to DS - <br />7000 series adhesives when joining <br />secondary containment fittings. <br />Electric heating collars and chemi- <br />cal heat packs can be used to speed <br />up DS -7000 series adhesive cure <br />time. DS -7000 series adhesives are <br />not UL Listed for alcohol or alcohol - <br />gasoline mixtures. <br />For complete instructions on adhe- <br />sive mixing, joint assembly, and <br />adhesive curing, see Smith Fiber- <br />glass Products Manual No. B2160. <br />Nominal <br />Nominal <br />Nominal <br />Nominal <br />Nominal <br />Mill Test <br />Random <br />Pipe Size <br />®. D. <br />I. D. <br />Wall Thickness <br />Weight <br />Pressure -Temp. <br />Pressure <br />Lengths <br />(in.) <br />(in.) <br />(in.) <br />(in.) <br />(lbs./ft.) <br />Max. Rating <br />(psig) <br />(it.) <br />2 <br />2.375 <br />2.235 :;. <br />0.070 <br />0.4 <br />250 psig @ 150° F <br />375 <br />15 <br />30 <br />3 <br />3.500 <br />3.360 <br />0.070 <br />0.6 <br />175 psig @ 150° F <br />265 <br />15 <br />30 <br />4 <br />4.500 <br />4.360 <br />0.070 <br />0.8 <br />125 psig @ 150° F <br />265 <br />15 <br />30 <br />Nominal <br />Nominal <br />Nominal <br />Nominal <br />Nominal <br />Mill Test <br />Random h <br />Pipe Size <br />D. D. <br />1. D., <br />Wall Thickness <br />Weight <br />Pressure -Temp. <br />Pressure <br />Lengths <br />(in)� <br />(mm <br />(mm) <br />(mm): <br />(Icglen <br />IUIax.Rating <br />(MPa) <br />� ,•(m)�, ,. <br />2 <br />60.33 <br />56.77- <br />- 1.78, <br />0.60 <br />.72 MPa @ 66.50 G <br />;.2.59 - <br />14.6 <br />9.1 <br />3-: <br />88.90 <br />85.34 <br />1.78 <br />0.89:. <br />1.21:1MPa @ 66.5° C <br />1.83 <br />4.6 <br />Al <br />4 .. <br />114.30 <br />110.74 <br />1.78 <br />1.19,0.86 <br />MPa @ 66.5° C <br />1.83 <br />4.6 <br />9.1 <br />(1) All values except pressure -temperature maximum rating are nominal values. Tolerances (2) All sizes can accept full vacuum pressures <br />or maximum/ minimum limits can be obtained from Smith Fiberglass Products Inc. at maximum temperature ratings. <br />It is the policy of Smith Fiberglass Products to improve its <br />products continually. In accordance with that policy, the <br />right is reserved to make changes in specifications, <br />descriptions and illustrative material contained in <br />this bulletin as conditions warrant. The information <br />contained herein is general in nature and is not intended <br />to express any warranty of any type whatsoever nor <br />shall any be implied. <br />2700 West 65th Street 1 Little Rock, Arkansas 72209 a Telephone (501) 568-4010 a T?tlix (910) 722-7377 a FAX (501) 568-4465 <br />® Copyright Smith Fiberglass Products Inc. 1990. <br />0 and TNI Trademarks of Smith Fiberglass Products Inc. PRINTED IN U.S.A. 7.5M291 <br />■ <br />
The URL can be used to link to this page
Your browser does not support the video tag.