My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1989-2008
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MICHAEL CANLIS
>
7000
>
2300 - Underground Storage Tank Program
>
PR0232437
>
COMPLIANCE INFO_1989-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2020 12:52:20 AM
Creation date
6/3/2020 9:57:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1989-2008
RECORD_ID
PR0232437
PE
2361
FACILITY_ID
FA0003787
FACILITY_NAME
SHERIFFS OPERATIONS CTR #1
STREET_NUMBER
7000
Direction
N
STREET_NAME
MICHAEL CANLIS
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95231
APN
19305014
CURRENT_STATUS
01
SITE_LOCATION
7000 N MICHAEL CANLIS RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232437_7000 N MICHAEL CANLIS_1989-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
427
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNIFIED PROGRAM CONSOLIDATED FORM <br /> TANKS <br /> UNDERGROUND STORAGE TANKS-TANK PAGE 1 6 f' <br /> (two pages per tank) <br /> Page 2of <br /> TYPE OF ACTION ❑1.NEW SITE PERMIT ❑ 4. AMENDED PERMIT ❑ 5. CHANGE OF INFORMATION) ❑ 6. TEMPORARY SITE CLOSURE <br /> (Check one item only) ❑ 7. PERMANENTLY CLOSED ON S1TE <br /> ❑3.RENEWAL PERMIT (Specify reason-for local use only) (Specify charge-for Neal use only) ❑ B. TANK REMOVED 430 <br /> BUSINESS NAME(Same as FAC LITY NA or DBA-Doing Business As FACILITY ID 0 1 <br /> &at,u -*- / I hr <br /> LOCATION WI WSITE(Op#onaq 431 0 <br /> 1.TANK DESCRIPTION <br /> TANK ID# TANK MANUFACTURER COMPARTMENTALIZED TANK ❑ Yes NoTft - <br /> •,n I o r i (D .i ,. If'Yes',complete one page for each comlfaWm ht. <br /> DATE INSTALLED(YEAR/MO) TANK CAPACITY IN GALLONS V <br /> NUMBER OF COMPARTMENTS <br /> - l 1s DOCS <br /> ADDITIONAL DESCRIPTION(Forlocal use only) <br /> 11.TANK CONTENTS <br /> TANK USE 432 PETROLEUM TYPE <br /> 1. MOTOR VEHICLE FUEL (1a. REGULAR UNLEADED ❑ 2. LEADED ❑ 5. JET FUEL <br /> (11 in. <br /> complete Petroleum Type) ❑1b. PREMIUM UNLEADED ❑ 3. DIESEL ❑ 6. AVIATION FUEL <br /> ❑ 2. NON-FUEL PETROLEUM ❑1c MIDGRADE UNLEADED ❑ 4. GASOHOL ❑99. OTHER <br /> ❑ 3. CHEMICAL PRODUCT COMMON NAME pCAS#(hom Hazardous Materials Inventory page) <br /> prom Hazardous Materials Inventory page) <br /> ❑ 4. HAZARDOUS WASTE(Includes <br /> Used 010 <br /> 95. UNKNOWN <br /> 111.TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1. SINGLE WALL ❑ 3. SINGLE WALL WITH ❑ 5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM <br /> (Check one dem only) )r2. DOUBLE WALL EXTERIOR MEMBRANE LINER ❑95. UNKNOWN <br /> ����11 ❑ 4. SINGLE WALL IN A VAULT ❑99 OTHER <br /> TANK MATERIAL-primary tank ❑ 1 BARE STEEL !. FIBERGLASS/PLASTIC ❑ 5. CONCRETE ❑95. UNKNOWN <br /> (Check one item only) ❑ 2. STAINLESS STEEL ❑4. STEEL CLAD WIFIBERGLASS *. FRP COMPATIBLE W/100%METHANOL ❑99. OTHER <br /> REINFORCED PLASTIC(FRP) <br /> TANK MATERIAL.secondary tank ❑ 1 BARE STEEL FIBERGLASS/PLASTIC FRP COMPATIBLE WI100%METHANOL ❑95. UNKNOWN <br /> (Check one item only) ❑ 2. STAINLESS STEEL ❑ 4. STEEL CLAD W/FIBERGLASS ❑ 9. FRP NON-CORRODIBLE JACKET ❑99. OTHER <br /> REINFORCED PLASTIC(FRP) ❑10 COATED STEEL <br /> ❑ 5. CONCRETE <br /> TANK INTERIOR LINING ❑ 1. RUBBER LINED ❑ 3. EPDXY LINING ❑ 5. GLASS LINING C195. UNKNOWN433 DATE INSTALLED <br /> OR COATING ., Q/ <br /> ❑ 2. ALKYD LINING ❑ 4. PHENOLIC LINING 6. UNLINED ❑99. OTHER <br /> (Check one item on ) (For local use only) <br /> OTHER CORROSION ❑ 1. MANUFACTURED CATHODIC 3. FIBERGLASS REINFORCED PLASTIC ❑95. UNKNOWN 434 DATE INSTALLED <br /> PROTECTION IF APPLICABLE PROTECTION <br /> ❑ . IMPRESSED CURRENT ❑99. OTHER <br /> (Check one item only) ❑ 2. SACRIFICIAL ANODE (For local use only) <br /> SPILL AND OVERFILL YEAR INSTALLED TYPE(For local use only) OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED <br /> (Check all that apply) ❑ 1 SPILL CONTAINMENT y❑1 1. ALARM ❑ 3. FILL TUBE SHUT OFF VALVE <br /> C12. DROP TUBEKI[_ 2. BALL FLOAT J.q_U ❑ 4. EXEMPT <br /> ❑ 3. STRIKER PLATE qqT <br /> IV.TANK LEAK DETECTION <br /> IF SINGLE WALL TANK Check all that apply): IF DOUBLE WALL TANK OR TANK WITH BLADDER Check one item only): <br /> ❑ 1, VISUAL(EXPOSED PORTION ONLY) ❑ 5. MANUAL TANK GAUGING(MTG) ❑ 1. VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑ 2. AUTOMATIC TANK GAUGING(ATG) ❑ 6. VADOSE ZONE ❑ 2. CONTINUOUS INTERSTITIAL MONITORING <br /> ❑ 3. CONTINUOUS ATG ❑ 7. GROUNDWATER ❑ 3. MANUAL MONITORING <br /> ❑ 4. STATISTICAL INVENTORY RECONCILIATION(SIR)+ ❑ S. TANK TESTING <br /> BIENNIAL TANK TESTING ❑99, OTHER <br /> V.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> E5TJM TEE'D�DATE LAST USED(YRIMOIDAY) ESTIMATED QUANTITY OF SUBSTANCE REMAINING 435 1 TANK FILLED WITH INERT MATERIAL? <br /> ft gallons ❑Yes ❑No <br /> l g,�o <br /> CUPAFORM(4/99) ��0 Formerly SWRCB Form B <br />
The URL can be used to link to this page
Your browser does not support the video tag.