My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1990-2005
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
7373
>
2300 - Underground Storage Tank Program
>
PR0232494
>
COMPLIANCE INFO_1990-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/14/2023 12:43:48 PM
Creation date
6/3/2020 9:57:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1990-2005
RECORD_ID
PR0232494
PE
2361
FACILITY_ID
FA0002602
FACILITY_NAME
KAISER PERMANENTE
STREET_NUMBER
7373
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09416023
CURRENT_STATUS
01
SITE_LOCATION
7373 WEST LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232494_7373 WEST_1990-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
270
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ` NVIRONMENTAL HEALTH DEPARTMENT <br /> 304 East Weber Avenue,3`d Floor, Stockton,CA 95202-2708 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sjgov.or /g ehd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT <br /> Facility name: Designated Operator: Inspection Date: <br /> i <br /> Facility address: UST# <br /> QProduct <br /> Facility Contact: Title: Phone: <br /> Monitoring Panel: Piping system: Overfill prevention: <br /> v V� (mss 'LsV 1: ❑Pressurized Suction ❑Gravity echanical ❑Audible/visual <br /> ,Innspection type: Violations: <br /> Ca Routine 11)�.nitoring Certification ❑Installation ❑Other: ❑M1-RDetect M2-RPrev ❑M-3 Both <br /> VIOLATION(S)HSC=Califomia Health&Safety Code;CCR=California Code of Regulations V R <br /> # Code Section V <br /> V=Violation;RV=Re eat Violation <br /> 1 HSC 25284 Permit tooperate <br /> 2 CCR 2637 Secondary containment test performed <br /> 3 CCR 2711 b & c Current Unified Program Consolidated Forms on file with EHD(Facility and tank form <br /> 4 1 HSC 25292.2 Certification of financial responsibility and CFO letter <br /> 5 CCR 2632 c 2 D Monitoring&response plan is current and filed with the local agency <br /> 6 CCR 2712 i Monitoring&response plan is onsite <br /> 7 CCR 2712 b Maintenance&monitoring records Ml <br /> 8 CCR 2643 d) Daily monitoring of suction piping(pre-January, I, 1984 <br /> 9 HSC 25292.1 UST system isoperated to prevent unauthorized release <br /> 10 CCR 2632(c)(2) UST monitoring system is present Ml <br /> 11 CCR 2630 d UST system monitoring equipment is properly located to detect a leak MI <br /> 12 HSC 25291 UST system monitoring equipment isoperational M2 <br /> 13 CCR 2636 1 Continuous monitoring system for underground piping&UDC is present M1 <br /> 14 CCR 2631 a Primary containment is product tight <br /> 15 HSC 25291 (a)(2) Secondary containment for UST is tight <br /> 16CCR 2636(c)(1) All releases in secondary pipingflow to a collection sum <br /> 17 HSC 25291 Line leak detectors are installed Ml <br /> 18 CCR 2635(b)(1) Spill container M2 <br /> 19 CCR 2635(b)(2) Overfill prevention system M2 <br /> 20 CCR 2636(a) Conventional suction piping shall have continuous monitoring&2°containment <br /> 21 HSC 25291 (e) Water in 2°containment analyzed&properly disposed of <br /> 22 CCR 2650 Recording/reporting of unauthorized releases Ml <br /> 23 1 CCR 2715 Designated Operator:(a)Statement from UST owner; (c-e)Monthly inspection;( Employee training <br /> 24 CCR 2638 a Annual monitoring certification <br /> 25 CCR 2638(a) Annual line leak detector test Ml <br /> 26 HSC 25284.2 Annuals ill containment testing <br /> 27 CCR 2636 4 Annual line tightness test Ml <br /> 28 CCR 2661 Repair for tank/piping has had tightness test (M2 <br /> 29 CCR 2643 a Biennial tightness test of gravity piping( re-Januar 1, 1984 <br /> 30 CCR 2643 d Triennial line test for conventional suction piping(pre-January1,1984 Mi <br /> 31 HSC 25292.5 Double walls stem located within 1000'of public well-ELD <br /> 32 CCR 2661 Permit to repair UST system <br /> 33 HSC 25286 a Permit to alter monitoring system <br /> 34 HSC 25298 )`°" Permit to temporarily close UST system <br /> 35 HSC 25298(c) Permit to close UST system <br /> 36 HSC 25299(a)(9) Disabling leak detection devices <br /> 37 HSC 25298(a) Illegal abandonment of UST system <br /> 38 Other: <br /> EHD INSPECTOR- PHONE: UIC <br /> �(/ Septic system: <br /> _I Serves>_20 people/day <br /> RECEIVED Y TITLE: Receives other than sanitary waste <br /> Other disposal methods: <br /> wells/French Drains <br /> EHD 23-02-002 <br />
The URL can be used to link to this page
Your browser does not support the video tag.