My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2013
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
7373
>
2300 - Underground Storage Tank Program
>
PR0232494
>
COMPLIANCE INFO_2009-2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/14/2023 12:52:58 PM
Creation date
6/3/2020 9:57:23 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2013
RECORD_ID
PR0232494
PE
2361
FACILITY_ID
FA0002602
FACILITY_NAME
KAISER PERMANENTE
STREET_NUMBER
7373
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09416023
CURRENT_STATUS
01
SITE_LOCATION
7373 WEST LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232494_7373 WEST_2009-2013.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
429
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page Of <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: 0 Sump Manufacturer 0 industry Standard X Professional Engineer <br /> 0 Other(Specify) <br /> Test Method Used: 0 Pressure 0 Vacuum X Hydrostatic <br /> 0 Other(Specify) <br /> Test Equipment Used: Caldwell Systems Equipment Resolution: .005/30 min <br /> MINEEMEM <br /> Sump#I Sump# Sump# Sump# <br /> Sump Diameter: : 4211 <br /> Sump Depth: 6011 <br /> Sump Material: Fiberglass <br /> Height from Tank Top to Top of 2491 <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 2777 <br /> Electrical Penetration: <br /> Condition of sump prior to testing: Dry <br /> Portion of Sump Tested' 2"above Highest piping penetration <br /> Does turbine shut down when <br /> sump sensor detects liquid(both 0 Yes 0 No 0 NA DYes ONo DNA 0 Yes 0 No 0 NA 0 Yes 0 No 0 NA <br /> product and water)?* <br /> Turbine shutdown response time <br /> Is system programmed for fail-safe 0 Yes 0 No 0 NA 0 Yes 0 No 0 NA DYes ONo DNA DYes ONo DNA <br /> shutdown?* <br /> Was fail-safe verified to be 0 Yes 0 No 0 NA 0 Yes 0 No 0 NA 0 Yes 0 No 0 NA 0 Yes 0 No 0 NA <br /> operationalf <br /> Wait time between applying <br /> pressure/vacuum/water and starting 5 min 5 min 5 min 5 min <br /> test: <br /> Test Start Time: <br /> Initial Reading(Ri): .001, .001, .0091 .001, <br /> Test End Time: <br /> Final Reading(RF): <br /> Test Duration: 30 min 30 min 30 min 30 min <br /> Change in Reading(RF-Ri): <br /> Pass/Fail Threshold or Criteria: .005/30 min .005/30 min .005/30 min .005/30 min <br /> Test Result: 0 Pass x Fail 0 Pass 0 Fail 0 Pass 0 Fail 0 Pass 0 Fail <br /> Was sensor removed for testing? x Yes 0 No 0 NA x Yes 0 No 0 NA x Yes 0 No 0 NA OYes ONo DNA_ <br /> Was sensor properly replaced and x Yes 0 No 0 NA x Yes 0 No 0 NA x Yes 0 No 0 NA 0 Yes 0 No 0 NA <br /> verified functional after testing? I I <br /> Comments—(include information on repairs made pHor to testing, and recommended follow-up for failed tests) <br /> Sump will not hold water. Pipe penetrations cut off at sump wall <br /> If the entire depth of the sump is not tested,specify how much was tested. If the answer to gpy of the questions indicated with an <br /> asterisk(*)is"NU'or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.