Laserfiche WebLink
1549 Cummins Drive <br /> 1 Modesto, CA 95358 <br /> Co.,111 MacDonald Phone: 209.576.0726 <br /> serving you since 1956 Fax: 209.576.1312 <br /> www,rfmacdonald.com <br /> Kaiser Stockton January 11,2012 <br /> 7373 West Lane <br /> Stockton, CA 95210 <br /> Phone: 662-4309 l e <br /> Attention: Dana Feiock R r. <br /> Reference: Fulton Cal Special <br /> Quotation#: Pages:3 <br /> Thank you for this opportunity to provide you with a quotation for the following equipment: <br /> Fulton ICS-9.5 HP Cal Special <br /> One(1) Fulton Model ICS-9.5 California Special self-contained packaged forced draft vertical tubeless steam boiler, <br /> rated for 9.5 boiler horsepower,398,400Btu/Hr input,capable of producing 328#11-Ir steam.This unit is fully automatic for <br /> gas firing an#2 oil and is intended for indoor use and will consist of a vertical tubeless boiler, boiler fittings, burner <br /> equipment and automatic controls. <br /> a <br /> Both boiler and bumer will be the product of the same manufacturer to insure <br /> undivided responsibility and simplified servicing. Boiler design and,construction will be <br /> in accordance with ASME Section I(IV)Boiler Code,and the complete packaged unit <br /> will bear Underwriters'Laboratories Label. The boiler will meet all applicable <br /> requirements of the State of Califomia Boiler and Fired Pressure Vessel Safety Orders <br /> and ASME CSD-1 Safety Code. <br /> Boiler Features and Trim <br /> • Natural Gas and#2 oil firing <br /> • Slowdown valves for water column <br /> • Manual surface blowdown kit <br /> • Feed water stop valve and spring check valve <br /> • Water gauge glass protector <br /> • Complete burner assembly <br /> • Diagnostic Display Module <br /> • Feedwater Solenoid <br /> • NEMA 1 Control Panel with wiring diagram <br /> • Boiler Alarm Package including high water,low water,flame failure alarm <br /> horn and silence switch, general alarm output contacts. <br /> • Operating and High Limit Pressure Switches <br /> • Two Low Water Cutoff devices <br /> • CSD-1 Compliant <br /> • UL Listed Compliant <br /> Gas Requirements <br /> The standard gas pressure regulator furnished with the boiler provides for a maximum inlet gas pressure of 11"W.C. <br /> and a minimum 7"W.G. If the inlet gas pressure exceeds 11"W.C., a second gas pressure regulator must be field <br /> installed upstream of the standard regulator. We have not included a second regulator unless the boiler specifications <br /> indicated a gas pressure in excess of 11"W.C. <br />