COMPLIANCE INFO_2009-2013
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
7373
>
2300 - Underground Storage Tank Program
>
PR0232494
>
COMPLIANCE INFO_2009-2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/14/2023 12:52:58 PM
Creation date
6/3/2020 9:57:23 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2013
RECORD_ID
PR0232494
PE
2361
FACILITY_ID
FA0002602
FACILITY_NAME
KAISER PERMANENTE
STREET_NUMBER
7373
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09416023
CURRENT_STATUS
01
SITE_LOCATION
7373 WEST LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232494_7373 WEST_2009-2013.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
429
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OPQU1jv C <br /> �• -t'_o SAN JOAQUIN COUNTY <br /> Q• <br /> rr� a *ENVIRONMENTAL HEALTH DEPARTMENS <br /> 1868 East Hazelton Avenue, Stockton, CA 95205-6232 <br /> Telephone: (209) 468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd <br /> ORS <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM SERVICE REQUEST INSPECTION REPORT <br /> Facility Name: Inspection Date: <br /> f5' 6 /3 <br /> Fac lity Address: Service Request#: <br /> -- 6oJ <br /> Onsite Service Technician's Name: ICC Service Technician/Installer Exp.Date: Manufacturer Training: <br /> s <br /> x- z _6 �v - 1- ls <br /> SERVICE SERVICE <br /> Leak detector <br /> El mechanical Model: Spill bucket El minimum 5 gallon <br /> ❑ El electronic Serial: El 1 hour hydrostatic ❑ Incon TS-STS <br /> El line test ro rammed El Caldwell System ❑ Other <br /> Leak detector Spill bucket ❑ minimum 5 gallon <br /> ❑ ❑ mechanical Model: ❑ ❑ 1 hour hydrostatic ❑ Incon TS-STS <br /> ❑ electronic Serial#: ❑ Caldwell System ❑ Other <br /> ❑ line test programmed <br /> sensor <br /> El positive shutdown Model: ElPrimaps piping testing at: <br /> ❑ fail safe Serial#: minutes <br /> ❑ NA <br /> sensor Secondary containment testing for <br /> El ❑ positive shutdown Model: UDC(s) J, rr-- Piping <br /> ❑ fail safe Serial#: Sump(s) UST(s) <br /> ❑ NA <br /> sensor Testing for the above components are next due by: <br /> ❑ ❑ positive shutdown Model: / � 7Z. 13 ! 1,41I/Y4%1 S-z <br /> ❑ fail safe Serial#: r <br /> Note: Please be aware that 21 containment components are req fired to be tested upon <br /> ❑ NA installation,6 months after,and every 36 months thereafter. <br /> ❑ Drop tube with mechanical overfill at 95% ❑ Cold start of monitoring panel <br /> JEOverfill <br /> Drop tube with mechanical overfill at 95% ElCorrosion protection <br /> prevention (see LIS letter 150-1) ❑ Other: see below <br /> This UST facility is APPROVED to operate ❑ This UST facility is NOT APPROVED to operate <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> EHD R 4#Ins pe Re 'ved�y: Title: <br /> VV,/—, VV, W � Lo'- <br /> EHD 23-04 L UST SERVICE REQUEST INSPECTION REPORT <br /> Rev 4/30/12 <br />
The URL can be used to link to this page
Your browser does not support the video tag.