My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2014-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
7373
>
2300 - Underground Storage Tank Program
>
PR0232494
>
COMPLIANCE INFO_2014-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/23/2023 1:27:31 PM
Creation date
6/3/2020 9:57:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2014-2018
RECORD_ID
PR0232494
PE
2361
FACILITY_ID
FA0002602
FACILITY_NAME
KAISER PERMANENTE
STREET_NUMBER
7373
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09416023
CURRENT_STATUS
01
SITE_LOCATION
7373 WEST LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232494_7373 WEST_2014-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
324
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MAHN Environmental Health Department <br /> COUNTY-- <br /> �'n ea OeA "M <br /> oar nl� o( V <br /> M, <br /> 21-1 'RA <br /> um <br /> Facility Name: Facility Address: Date: <br /> KAISER PERMANENTE 7373 WEST LN, STOCKTON June 28,2018 <br /> US. <br /> ,stem Ob�rvatton •. <br /> 319 CCR 2635(b) No spill bucket,failed to contain five gallons,or failed to provide a means to keep it empty o V o R o COS <br /> 320 CCR 2635(b)(2) Overfill prevention system not present or failed to meet overfill requirements ii V c R o COS <br /> 321 CCR 2635(b)(2) Overfill prevention was overridden o V o R c COS <br /> 322 HSC 25281.6(a) Unburied below grade emergency generator system failed to meet exemption status ii V o R ii COS <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status o V o R o COS <br /> 324 CCR 2717.1(g) Tampered with red tag Ei V Ei R Ei COS <br /> 325 CCR 2717.1(f) Deposited petroleum into a red tagged UST Ei V c R o COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms o V o R ii COS <br /> 327 CCR 2631.1 UST system not compatible with the substance stored c V o R o COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements c V o R Ei COS <br /> 329 HSC 25298 Failed to comply with all permanent closure requirements c V ii R Ei COS <br /> 330 CCR 2636(f)(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system o V o R o COS <br /> 331 CCR 2630(d) Secondarily contained piping not maintained to allow liquid to drain into sump o V [D R o COS <br /> 332 CCR 2631(b),2631(d) Primary and/or secondary containment not constructed in accordance with the established standards ci V Ei R Ei COS <br /> TRR <br /> 7MF':777:'7 <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve u V o R c COS] <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed o V ii R Ei COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) Ei V o R o COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) o V Ei R ci COS <br /> R, <br /> 2010 See below Unlisted General violation o V o R o COS <br /> 'UM <br /> LASM^LA-R 0 <br /> '(c omp <br /> ..... .. k"ftLCLASS,I1 <br /> Item# Remarks <br /> 314 HSC 25290.1, 25290.2, 25291 Failed to have secondary containment or secondary containment not tight. <br /> The 12/06/2017 secondary containment test results indicate a failure at the diesel piping sump. Service request <br /> SR0078867 needs revisions and approval prior to repair of the diesel piping sump.All secondary containment for <br /> the UST system must be tight. Immediately have a properly licensed,trained, and certified contractor repair or <br /> replace the failed component under permit and inspection of the EHD. <br /> This is a Class 11 violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork within 30 days of receipt of this report. <br /> FA0002602 PR0232494 SCO01 06/2812018 <br /> EHD 23-01 Rev.10/31/2017 Page 3 of 4 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 w\Aw.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.