My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
633
>
2300 - Underground Storage Tank Program
>
PR0232519
>
COMPLIANCE INFO_2009-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2024 2:00:21 PM
Creation date
6/3/2020 9:57:37 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2015
RECORD_ID
PR0232519
PE
2361
FACILITY_ID
FA0000483
FACILITY_NAME
BILLS 76
STREET_NUMBER
633
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04321055
CURRENT_STATUS
01
SITE_LOCATION
633 E VICTOR RD STE A
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232519_633 E VICTOR_2009-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
384
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.smgov.o[g/ehd/unitiii.html <br />CONTINUATION FORM <br />Page: 3 of 4 <br />OFFICIAL INSPECTION REPORT <br />Date: 07/01/10 <br />Facility Address: Bill's 76 633 E. Victor Rd. Lodi, CA 95240 <br />Program: UST <br />SUMMARY OF VIOLATIONS <br />CLASS I CLASS 0, or MINOR -Notice to Com <br />Violations: # 2, 17, 23d. Repeat Violations: # 7, 21, 23c, 24. <br />#2 This office received notification on 1-20-09 that secondary containment testing would be performed <br />on 1-30-09. Copy of test results must be submitted to this office within 30 days of the test date. This <br />office has not yet received a copy of the secondary containment test results. Correct immediately by <br />submitting a copy of the secondary containment test results from the 1-30-09 testing to this office. <br />#7 Maintenance records were not available for review for the following alarms: L4 91 annular low and <br />high liquid alarms on 7-17-09; sensor out alarms for L1 91 stp sump, L2 89 stp sump, L3 91 stp sump on <br />8-19-09; sensor out, high, and low liquid alarms for L4 91 annular, L5 89 annular, and L6 87 annular on <br />8-19-09. Maintenance records for alarms must be maintained for 3 years. Correct immediately. Submit <br />copies of maintenance records for these alarms to this office by 8-1-10. <br />#17 The 89 VMI line leak detector failed the 3 gal/hr at 10psi leak test. Technician corrected this during <br />the inspection by adjusting the 89 VMI line leak detector and retested it to pass. <br />#21 Approximately 1 quart of water was in the 87 stp sump. Technician corrected this during the <br />inspection by removing the water and placing it into the hazardous waste drum on site. <br />#23c Designated operator (D.O.)reports from August 2009 through March 2010 list 2-24-09 as the date <br />of the most recent monitoring system certification testing. The date should be 7-16-09. The D.O. has <br />also listed date for the annual line test as 2-24-09 and 7-16-09. This is not accurate since positive <br />shutdown on turbines has been verified. 87 line test was last done 2-4-09 and 87,89, & 91 line test were <br />done 4-1-08. D.O. must completely and accurately complete the monthly D.O. report including <br />documentation of test dates. Correct immediately by ensuring that the D.O. does this. <br />#23d The two employees on site did not have documentation on site indicating that they have been <br />trained by the D.O. within the past twelve months. According to the records available on site, Faisal Baz <br />and Lisa Clark were most recently trained on 6-15-09 by the D.O. D.O. employee training must be <br />current for at least one employee on site. Correct immediately. Have the D.O. conduct and document the <br />required training and submit a copy of it to this office. <br />#24 The test results from the annual monitoring system certification testing on 7-16-09 were not received <br />by this office till 9-17-09. Test results must be submitted within 30 days of the test. Begin the practice of <br />ensuring that copies of the test results are submitted within 30 days of the test. <br />ALL EHD STAFF 7111E ASSOCIATED WITH FALING TO COMPLY BY THE ABOVE NOTED DATES WALL BE BILLED AT THE CURRENT HOURLY RATE ($11 <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT AN E AT EHD'S CURRENT HOURLY RATE. <br />EHD Inspector: <br />Received By: <br />Title: <br />` <br />\ <br />J <br />� QI <br />V <br />EHD 23-02-003 Rev 06/01/10 CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.