My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1960
>
2300 - Underground Storage Tank Program
>
PR0232534
>
COMPLIANCE INFO_2011-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:32 AM
Creation date
6/3/2020 9:57:50 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2015
RECORD_ID
PR0232534
PE
2361
FACILITY_ID
FA0004547
FACILITY_NAME
CHEVRON STATION #201383
STREET_NUMBER
1960
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23402001
CURRENT_STATUS
01
SITE_LOCATION
1960 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232534_1960 W ELEVENTH_2011-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
323
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County FEB 12 2015 <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, Califorrila96206-6232 <br /> NVIRONMENTA <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web;wvvw.sJgoV.ocg/ehd <br /> a ;Pry h <br /> FAM. <br /> d' <br /> Facility Name: Facility Address: Date: <br /> CHEVRON STATION 42013.83 1960 W ELEVENTH ST,TRACY rebruary 06, 2015 <br /> T i(ei* <br /> 322 CCR 2W6(f)(2) Line leek detector not Installed o V a R 000S <br /> 323 CCR 2636(f)(2) Leak detector Palled to doted a 10 gph leak at 10 pal [3 V o R c COS <br /> 324 CCR 2635(b) No spill bucket Installed or failed to provide a means to keep It empty o V a R o COS <br /> 325 CCR 2636(b) Spill container failed to contain a minimum capacity of five gallons a V c3 R C3 008 <br /> 326 CCR 2635(b)(2) Overfill prevention system not present,was overridden,or failed to meet overfill requirements m V a R 13 COS <br /> 327 HSC 25283.5 Unburied below grade UST failed to meet exemption status a V a R a COS <br /> 326 CCR 2717,1(g) Tampered with red too 0 V a R COOS <br /> 329 CCR 2717.1(1) Deposited petroleum into a red tagged UST a o a COS <br /> 330 HSC 25299(1)(2) Tampered with or disabled leak detection devices or alarms a V 0 R a COS <br /> 331 CCR 2631.1 UST system not compatible wfth.the substance stored a V o R a COS <br /> 332 HSC 25298(b) Failed to comply with temporary closure requirements o V a R oCOS <br /> 333 HSC 25298(c) Failed to comply with permanent closure requirements a V o R o COS <br /> 401 CCR 2630(a)(3) Suctlon piping not properly sloped or incorrectly located check vulva o V o R o COS <br /> 402 CCR 2643(d) Dally monitoring of suction pipe(pre-Jan 1984)not performed o V o R a COS <br /> 403 CCR 2643(4) Triennial 0.1 gph line test for conventional suction piping not performed(pr&January 1984) o V o R o COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) c V b R a COS <br /> 77 <br /> 2010 See below Unlisted Administration/Documentation viol2tlon o V o R a COS <br /> 2030 Sea below -Unlisted Operationa/Maintenance violation a V o R a COS <br /> 2050 See below Unlisted Design/Construction violation m V a R a COS <br /> "MAX" "05,M)OLAT'llb <br /> YY <br /> C <br /> Itarn# Remarks <br /> 3221 CCR 2636(f)(2)Leak detector failed to detect a 3.0 gph leak at 10 psL <br /> The 91 line leak detector failed to detect a leak when tested. All line leak detectors shall be capable of detecting a <br /> 3-gallon per hour leak at 10 psi. The leak detectorwas replaced and retested during the inspection. A'UST <br /> Retrofit Verification with Inspector Al ready Onsite"form has been completed and provided to the operator and <br /> contractor. <br /> This Is a Class 11 violation. <br /> I <br /> Overall Inspection Comments: <br /> Consent to perform the inspection, take photos and collect samples was given by Helen McCarty, Store Manager <br /> . This facility's designated operator Is Elijah Pendergraft(ICC expiration date: 6116) . The service technician was <br /> Gilbert Garcia (ICC expiration date: 7/15), who had the following manufacturer's certifications: Veeder Root 3/15, <br /> VMl 3/15, <br /> go-relvad 115y(InIffal); napector one; Date: <br /> MICHELLE HENRY, Senior REB <br /> (209)468-3454 0210612015 <br /> Page <br /> wk_� <br />
The URL can be used to link to this page
Your browser does not support the video tag.