My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2015-2016
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1960
>
2300 - Underground Storage Tank Program
>
PR0232534
>
COMPLIANCE INFO_2015-2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:32 AM
Creation date
6/3/2020 9:57:57 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2015-2016
RECORD_ID
PR0232534
PE
2361
FACILITY_ID
FA0004547
FACILITY_NAME
CHEVRON STATION #201383
STREET_NUMBER
1960
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23402001
CURRENT_STATUS
01
SITE_LOCATION
1960 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\E\ELEVENTH\1960\PR0232534\RETROFIT 2015.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
447
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />1 <br />Date: <br />CHEVRON STATION #201383 <br />1960 W ELEVENTH ST, TRACY <br />January 25, 2016 <br />SUMMARY OF VIOLATIONS <br />(CLASS t, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />207 <br />CCR 2715 Designated operator did not inspect all required items and/or the inspection reports not completed. <br />The designated operator failed to document all the alarms from the attached alarm history on the September 9, <br />2015 designated operator monthly inspection report and failed to check that they were responded to appropriately. <br />The missing alarms include: Tank 3 (87 product) overfill alarm on August 28, 2015. During the monthly inspection, <br />the designated operator shall review the alarm history for the previous month, check that each alarm was <br />documented and responded to appropriately, and attach a copy of the alarm history with documentation taken in <br />response to any alarms to the monthly report. Ensure that designated operators performing monthly inspections at <br />this facility are including all of the required information on the reports. <br />This is a minor violation. <br />307 <br />CCR 2632(c) Monitoring system of the interstitial space of a double walled system not maintained. <br />The diesel annular sensor failed to activate an audible and visual alarm when tested and, therefore, the tank is not <br />monitored. The interstitial space shall be monitored with a monitoring system connected to an audible and visual <br />alarm system. The sensor, model number 0794390-409, was replaced, like for like, and retested during the <br />inspection. A "UST Retrofit Verification with Inspector Already Onsite" form has been completed and provided to the <br />operator and contractor. <br />Th~ s was corrected on site. <br />This is a Class II violation. <br />325 <br />CCR 2635(b) Spill container failed to contain a minimum capacity of five gallons. <br />The 87, 91 and diesel spill container failed to have a minimum capacity of five gallons. All spill containers shall have <br />a minimum capacity of five gallons. Immediately contact a properly licensed, trained, and certified contractor to <br />repair or replace the spill container under permit and inspection of the EHD. During the inspection, the service <br />technician repaired the diesel spill container by replacing the drain valve and o-ring, and the service technician <br />replaced the o-rings on the 91 and 87 spill buckets. <br />This was corrected on site. <br />This is a minor violation. <br />Overall Inspection Comments: <br />On site on January 25, 2016, to conduct a routine UST monitoring system certification, spill container and line <br />leak detector inspection. A Return to Compliance Certification form and inspection report were left at the site at <br />the time of the inspection. <br />Complete and submit a copy of the Return to Compliance Certification form to the San Joaquin County <br />Environmental Health Department with a statement documenting the corrective actions that have been or will be <br />taken for each violation, and any supporting paperwork, by February 24, 2016. <br />Please be aware that following upgrades to this service station, facility operators are required to upload the <br />following UST program documents into the California Environmental Reporting System (CERS): UST Monitoring <br />Site Plan (change of sensor model number); UST product contents revised for each tank, under dispenser <br />Received by n <br />Inspector: <br />Phone: <br />Date: <br />(initial): Z�- <br />VICKI MCCARTNEY, Senior REHS <br />(209) 468-9852 <br />01/25/2016 <br />Page 4 of 5 <br />
The URL can be used to link to this page