My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MANTHEY
>
2224
>
2300 - Underground Storage Tank Program
>
PR0232555
>
COMPLIANCE INFO_2007-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2023 4:34:08 PM
Creation date
6/3/2020 9:58:15 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2015
RECORD_ID
PR0232555
PE
2361
FACILITY_ID
FA0003679
FACILITY_NAME
CALIFORNIA STOP*
STREET_NUMBER
2224
STREET_NAME
MANTHEY
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
16313007
CURRENT_STATUS
01
SITE_LOCATION
2224 MANTHEY RD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\M\MANTHEY\2224\PR0232555\PERMANENT INJUNCTION 7-19-07.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
446
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Piping system Secondary employs full-performance pipe—Many contained fuel handling systems <br /> characteristics employ materials in the secondary that fall far short of the primary piping in regards to <br /> chemical resistance and mechanical strength.By contrast,Dualoy 3000/L systems <br /> employ the same type of high-performance fiberglass-reinforced pipe in the secondary as <br /> in the primary.Thus,Dualoy 3000/1-containment systems easily withstand both high <br /> external loads from backfill and traffic as well as internal pressures as high as 100 psig. <br /> Compact containment fittings—Dualoy 3000/L containment fittings are more compact <br /> than competitive clam-shell type closure pieces.As a result,crossovers in a Dualoy <br /> 3000/L system occupy less space,so less excavation is required than with competing <br /> rigid-wall containment systems. <br /> Precision pipe exterior eliminates scarfing—Dualoy pipe is manufactured in a <br /> proprietary continuous winding process that provides an extremely precise,consistent <br /> outside diameter.No scarring of the pipe end is required to achieve a proper fit of the <br /> secondary pipe inside closure pieces.Light sanding of the pipe end to remove the surface <br /> Only end prep required <br /> gloss and obtain a suitable bonding surface is the only end prep required. <br /> is the removal bylight Easy containment fitting assembly—Dualoy 3000/L containment fitting clamshells <br /> sanding of surface <br /> gloss. are supplied in matched pairs.One half of each pair is fitted with pre-inserted propeller <br /> nuts,allowing the fitting to be assembled from one side,using the bolts provided. <br /> Complete retestability— Dualoy 3000/1-containment employs rigid-wall pipe and <br /> fittings that maintain their shape during the entire service life of the station.When installed <br /> with isolating penetration fittings(see page 4),Dualoy 3000/L containment piping can be <br /> repeatedly retested whenever desired. <br /> Convenient repair capability—Contained piping systems are occasionally damaged <br /> after installation.Damage is generally caused by paving or excavation operations.Dualoy <br /> 3000/L contained piping systems are designed so that only the damaged stretch need be <br /> replaced instead of the entire line.The 2-inch Dualoy repair coupling is sized so that it can <br /> be contained within 4-inch Dualoy 3000/L containment pipe. <br /> 4 x 3 inch reducing <br /> Two-inch primary pipe contained within couplings <br /> 3-inch containment pipe can be repaired <br /> with a UL-listed 2-inch repair 2-inch repair coupling <br /> coupling.The containmentis restored by , 0 ° <br /> replacement of a section of the existing0 0 0 0 <br /> containmentpipe with a 4-inch --- -------"----- --- <br /> containment nipple.The 4-inch — — — — <br /> replacement nipple is then joined to the ___ ------_______ <br /> existing containment pipe with Dualoy 0 0 00J I <br /> reducing couplings. 0 0 0 0 <br /> Align wing-nuts parallel to pipe to permit <br /> 4-inch pipe 4-inch pipe to slip over repair coupling <br /> 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.