Laserfiche WebLink
III-TANK SETUP <br /> C01,11,1UNICATIONS SETUP <br /> - - - - - - - - - - - - <br /> T 1 :87 UNLEADED <br /> PRODUCT CODE <br /> PORT SETTINGS: THERMAL COEFF : .000700 <br /> TANK DIAMETER 92.00 <br /> COMM BOARD 3 (RS-232) TANK PROFILE 20 PTS <br /> BAUD RATE 1200 FULL VOL 11627 <br /> PARITY ODD 87.4 INCH VOL 11439 <br /> STOP BIT I STOP 82.8 INCH VOL 11066 <br /> DATA LENGTH: 7 DATA 78.2 INCH VOL 10600 <br /> RS-232 SECURITY 73.6 INCH VOL 10049 <br /> CODE : DISABLED 69.0 INCH VOL 9438 <br /> LINE RE-ENABLE METHOD 64.4 INCH VOL 877459.8 INCH VOL 8089 <br /> PASS LINE TEST AUTO TRANSMIT SETTINGS: 55.2 INCH VOL 7352 <br /> LINE PER TST NEEDED WRN 50.6 INCH VOL 6591 <br /> DISABLED AUTO LEAK ALARM LIMIT 46.0 INCH VOL 5814 <br /> LINE ANN TST NEEDED WRN DISABLED 41 .4 INCH VOL 4870 <br /> DISABLED AUTO HIGH WATER LIMIT 36.8 INCH VOL 4296 <br /> DISABLED 32.2 INCH VOL 3558 <br /> PRINT TC VOLUMES AUTO OVERFILL LIMIT 27.6 INCH VOL 2853 <br /> ENABLED DISABLED 23.0 INCH VOL 2190 <br /> AUTO LOW PRODUCT 18.4 INCH VOL 1578 <br /> TEMP COMPENSATION :13.8 INCH VOL 1042 <br /> VALUE (DEG F ) : 60.0 AUTO THEFT LIMIT 9.2 INCH VOL 573 <br /> STICK HEIGHT OFFSET DISABLED 4.6 INCH VOL 205 <br /> DISABLED AUTO DELIVERY START <br /> ULLAGE: 90% DISABLED <br /> AUTO DELIVERY END FLOAT SIZE: 4.0 IN. <br /> H-PROTOCOL DATA FORMAT DISABLED <br /> HEIGHT AUTO EXTERNAL INPUT ON WATER WARNING 2.0 <br /> DAYLIGHT SAVING TIME DISABLED HIGH WATER LIMIT: 3.0 <br /> DISABLED AUTO EXTERNAL INPUT OFF MAX OR LABEL VOL: 11627 <br /> RE-DIRECT LOCAL PRINTOUT DISABLED <br /> AUTO SENSOR FUEL ALARM OVERFILL LIMIT 95% <br /> DISABLED DISABLED 11045 <br /> WATER ALARM HIGH PRODUCT <br /> AUTO SENSOR 90% <br /> EURO PROTOCOL PREFIX 10464 <br /> DISABLED <br /> AUTO SENSOR OUT ALARM DELIVERY LIMIT 15% <br /> DISABLED 1744 <br /> SYSTEM SECURITY LOW PRODUCT 1000 <br /> CODE : 000000 RS-232 END OF MESSAGE LEAK ALARM LIMIT: 99 <br /> DISABLED SUDDEN LOSS LIMIT: 99 <br /> MAINTENANCE HISTORY TANK TILT 1 .93PROBE OFFSET 0.00 <br /> DISABLED <br /> COMMUNICATIONS SETUP - SIPHON MANIFOLDED TANKS <br /> TANK CHART SECURITY - - - - - - - - - TO: NONE <br /> DISABLED LINE MANIFOLDED TANKS <br /> PORT SETTINGS: TO: NONE <br /> CUSTOM ALARMS <br /> DISABLED COMM BOARD 3 (RS-232) <br /> BAUD RATE 1200 LEAK MIN PERIODIC: 30% <br /> PARITY ODD 3488 <br /> SERVICE NOTICE STOP BIT I STOP LEAK MIN ANNUAL 60% <br /> DISABLED DATA LENGTH: 7 DATA 6976 <br /> RS-232 SECURITY <br /> CODE DISABLED <br /> ISO 3166 COUNTRY PERIODIC TEST TYPE <br /> CODE: STANDARD <br /> MASS/DENSITY ANNUAL TEST FAIL <br /> DISABLED ALARM DISABLED <br /> PERIODIC TEST FAIL <br /> ALARM DISABLED <br /> GROSS TEST FAIL <br /> ALARM DISABLED <br /> ANN TEST AVERAGING: OFF <br /> PER TEST AVERAGING: OFF <br /> TANK TEST NOTIFY: OFF <br /> TNK TST SIPHON BREAK:OFF <br /> DELIVERY DELAY I MIN <br /> PUMP THRESHOLD 10.00% <br />