My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1992-2000
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1103
>
2300 - Underground Storage Tank Program
>
PR0232587
>
COMPLIANCE INFO_1992-2000
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2020 10:20:59 AM
Creation date
6/3/2020 9:58:23 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1992-2000
RECORD_ID
PR0232587
PE
2361
FACILITY_ID
FA0004521
FACILITY_NAME
CHEVRON USA #201761*
STREET_NUMBER
1103
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
APN
21935038
CURRENT_STATUS
01
SITE_LOCATION
1103 S MAIN ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232587_1103 S MAIN_1992-2000.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
323
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� • s <br />0 <br />D <br />Criterion for Declaring a Leak <br />3. This system <br />(X) uses a preset threshold <br />( ) measures and reports the output quantity and compares it to a predetermined threshold <br />to determine whether the pipeline is leaking. <br />4. This system <br />( X) uses a single test <br />( ) uses amultiple-test sequence consisting of tests (specify number of tests <br />required) separated by hours (specify the time interval between tests) <br />to determine whether the pipeline is leaking. <br />5. This system declares a leak if the output of the measurement system exceeds a threshold of <br />1.88 galffir (specify flow rate in gal/h) in 1 out of 1 tests (specify, for'example, 1 out <br />of 2, 2 out of 3). If more detail is required, please specify in the space provided. <br />Evaluation Approach <br />6. There are five options for collecting the data used in evaluating the performance of this <br />system. This system was evaluated <br />( X) at a special test facility (Option 0 <br />( ) at one or more instrumented operational storage tank facilities (Option 2) <br />( ) at five or more operational storage tank facilities verified to be tight (Option 3) <br />( ) at 10 or more operational storage tank facilities (Option 4) <br />( ) with an experimentally validated computer simulation (.Option 5 ) <br />pipelin <br />7. A total of - 53 tests were conducted on nonleaking tM between 7/8/91 (date) <br />and 7/20/91 (date). A description of the pipeline configuration used in the evaluation is <br />summarized in Attachment 3. <br />Answer questions 8 and 9 if Oprion 1, 2, or 5 was used. <br />8. The pipeline used in the evaluation was 2 in. in diameter, 219 ft long and <br />constructed of fiberglass (fiberglass, steel, or other). <br />9. A mechanical line leak detector <br />( ) was <br />(X) was not <br />present in the pipeline system. <br />Answer questions 10 and 11 if Option 3 or 4 was used. NA <br />10. The evaluation was conducted on (how many) pipeline systems ranging in <br />diameter from in. to in., ranging in length from ft to <br />ft, and constructed of (specify materials). <br />IPipeline Leak Detection System - Results Form <br />I I <br />Page 2 of 5 <br />