My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1992-2000
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1103
>
2300 - Underground Storage Tank Program
>
PR0232587
>
COMPLIANCE INFO_1992-2000
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2020 10:20:59 AM
Creation date
6/3/2020 9:58:23 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1992-2000
RECORD_ID
PR0232587
PE
2361
FACILITY_ID
FA0004521
FACILITY_NAME
CHEVRON USA #201761*
STREET_NUMBER
1103
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
APN
21935038
CURRENT_STATUS
01
SITE_LOCATION
1103 S MAIN ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232587_1103 S MAIN_1992-2000.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
323
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
f � � <br />0 <br />• the waiting time between the last delivery of product to the underground storage tank <br />and the.start of data collection for the test is NA h <br />• the waiting time between the last dispensing of product through the pipeline system <br />and the start of data collection for the test is 2.5 h <br />• the total data collection time for the test is 0.3 h <br />• the volume of the product in the pipeline system is less than twice the volume of the <br />product in the pipeline system used in the evaluation, unless a separate written <br />justification for testing larger pipeline systems is presented by the manufacturer, <br />concurred with by the evaluator, and attached to this evaluation as Attachment 8 <br />• please give any other limitations specified by the vendor or determined during the <br />evaluation: <br />Disclaimer.- This rest procedure only addresses the issue of the sysrem's abiliry to detect leaks in <br />pipelines. It does not rest the equipment for safety ha:ards or assess the operational <br />functionality, reliabiliry or maintainability of the equipment. <br />Attachments <br />Attachment 1 - Description of the System Evaluated <br />Attachment 2 - Summary of the Performance of the System Evaluated <br />Attachment 3 - Summary of the Configuration of the Pipeline System(s) Used in the Evaluation <br />Attachment 4 - Data Sheet Summarizing Product Temperature Conditions Used in the Evaluation <br />Attachment 5 - Data Sheet Summarizing the Test Results and the Leak Rates Used in <br />the Evaluation <br />Attachment 6 - Data Sheet Summarizing the Test Results and the Trapped Vapor Tests <br />Attachment 7 -- Data Sheet Summarizing the Test Results Used to Check the Relationship <br />Supplied by the Manufacturer for Combining the Signal and Noise <br />Certification of Results <br />I certify that the pipeline leak detection system was operated according to the vendor's <br />instructions. I also certify that the evaluation was performed according to the procedure <br />specified by the EPA and that the results presented above are those obtained during the <br />evaluation. <br />William D. Glauz Midwest Resarch Institute <br />( of person Krformin aluation) (organization performing evaluation) <br />425 Volker boulevard <br />(signature) (street address) <br />fig - - <br />au uct 7. 1991 Kansas City, MO 64110 <br />_ <br />(date) (city. state. zip) <br />(816) 753-7600 <br />(telephone number) <br />Pipeline Leak Detection System - Results Form Page 5 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.