Laserfiche WebLink
Ask AIML <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sjgov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CHEVRON USA#201761* 1 1103 S MAIN ST, MANTECA January 12, 2015 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 207 CCR 2715 Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator failed to include and/or review the alarm history pertaining to the February 14, 2014 <br /> designated operator monthly inspection report. During the monthly inspection, the designated operator shall review the <br /> alarm history for the previous month, check that each alarm was documented and responded to appropriately, and <br /> attach a copy of the alarm history with documentation taken in response to any alarms to the monthly report. Ensure <br /> that designated operators performing monthly inspections at this facility are including all of the required information on <br /> the reports. This is a repeat violation, Class II. <br /> 319 HSC 25291(e)Water in secondary containment not removed, analyzed, and properly disposed of(pre-Jul 2003). <br /> Liquid was observed in the UDC 9/10 sump. If water could enter into the secondary containment by precipitation or <br /> infiltration, it must be removed and disposed of properly. The service technician removed the observed liquid (less than <br /> 1 cup) utilizing absorbent pads and placed it in the onsite hazardous waste container pending disposal. Ensure that all <br /> sumps and annular spaces are maintained free of liquid. This is a Class II violation. This was corrected on site. <br /> 325 CCR 2635(b)Spill container failed to contain a minimum capacity of five gallons. <br /> The 91-octane spill container failed when tested. All spill containers shall have a minimum capacity of five gallons and <br /> be capable of containing a spill or overfill until it is detected or cleaned up. The technician onsite cleaned the drain <br /> valve and retested the spill container with passing results. This is a minor violation. This was corrected on site. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by February 11, 2015. <br /> Consent to perform the inspection, take photos and collect samples was given by Julie Kaderlik, the store <br /> manager. This facility's designated operator is Ellijah Pendergraft (ICC expiration date: June 2, 2016) . The <br /> service technician was Gilbert Garcia (ICC expiration date: July 11, 2015), who had the following manufacturer's <br /> certifications: VR: March 13, 2015 and VMI (TLD-5000): March 25, 2015. <br /> Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Owner/Operator: Written Agreement (if <br /> applicable), UST Letter from Chief Financial Officer, and Owner Statement of Designated UST Operator <br /> Compliance. <br /> ALL EHD STAFF TIME ASSOCIATED WTH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURREN1 HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received By(signatu ): Title: Date: <br /> eceiv y(printed name): Inspector: Inspector Phone: <br /> ELENA MANZO, REHS (209) 953-7699 <br /> Page 4 of 4 <br />