Laserfiche WebLink
qpww <br /> Appendix VI <br /> (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http://www.swrcb.ca.gov.) <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions within the State of Calftmla <br /> Authority Cited:Chapter 6.7,Health and Safety Code;Chapter 16,Division 3,Title 23,Callfornla Code of <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for each monitoring <br /> system control panel by the technician who performs the work.A copy of this form must be provided to the tank system owner/operator.The <br /> owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: CHEVRON 201761 Bldg.No.: <br /> Site Address: 1103 S.MAIN ST.PERMIT NUMB.N-3315 City: MANTECA Zip: 95337 <br /> Facility Contact Person: MGR-MARIE Contact Phone No.: 209-825-0174 <br /> Make/Model of Monitoring System: Veeder Root TLS 350 Date of Testing/Servicing: 1/14/2014 <br /> B.Inventory of Equipment Tested/Certifted <br /> Check the appropriate boxes to Indicatespecific equipment ins ected serviced: <br /> Tank ID: T1 Supreme-SUPREME Tank ID: T2 Regular 2-REGULAR <br /> ry In-Tank Gauging Probe. Model: mag (o In-Tank Gauging Probe. Model: ma <br /> P Annular Space or Vault Sensor. Model: 409 (V Annular Space or Vault Sensor. Model: 409 <br /> P Piping Sump/Trench Sensor(s). Model: 208 r Piping Sump/Trench Sensor(s). Model: 208 <br /> W Fill Sump Sensor(s). Model: 208 W Fill Sump Sensor(s). Model: 208 <br /> Mechanical Line Leak Detector. Model: [— Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Veeder Root PLLD rV_ Electronic Line Leak Detector. Model: Veeder Root PLLD <br /> IV Tank Overfill/High-Level Sensor.Model: flapper jV'Tank Overfill/High-Level Sensor.Model: flapper <br /> r Other(specify equipment a and model in Section E on Pa e 2). r Other(specify equipment a and model in Section E on Page 2). <br /> Tank ID: T3 Regular 1-REGULAR Tank ID: <br /> rV In-Tank Gauging Probe. Model: mag In-Tank Gauging Probe. Model: <br /> rV Annular Space or Vault Sensor. Model: 409 F Annular Space or Vault Sensor. Model: <br /> J-V Piping Sump/Trench Sensor(s). Model: 208 r Piping Sump/Trench Sensor(s). Model: <br /> 17 Fill Sump Sensor(s). Model: 208 r Fill Sump Sensor(s). Model: <br /> f— Line Leak Detector. Model: r Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Veeder Root PLLD r Electronic Line Leak Detector. Model: <br /> W Tank Overfill/High-Level Sensor.Model: flapper r Tank Overfill/High-Level Sensor.Model: <br /> r Other(specify a ui ment and model in Section E on Page 2). r Other(specify equipment a and model In Section E on Pae 2). <br /> Dispenser 1/2 Dispenser 3/4 <br /> ID: ID: <br /> IV Dispenser Containment Sensor(s).Model: 208 jV Dispenser Containment Sensor(s).Model: 208 <br /> r Shear Valve(s). Shear Valve(s). <br /> r Dispenser Containment Floats and Chain(s). r Dispenser Containment Floats and Chain(s). <br /> Dispenser 5/6 Dispenser 7/8 <br /> ID: ID: ft <br /> 17 Dispenser Containment Sensor(s).Model: 208 rV_ Dispenser Containment Sensor(s).Model: <br /> Shear Valve(s). rV_ Shear Valve(s). <br /> r Dispenser Containment Float(s)and Chain(s). r Dispenser Containment Float(s)and Chain(s). <br /> Dispenser 9/10 DDispenser 11/12 <br /> 171 Dispenser Containment Sensor(s).Model: 208 ]v` Dispenser Containment Sensor(s).Model: 7 <br /> 17 Shear Valve(s). Shear Valve(s). <br /> r Dispenser Containment Float(s)and Chain(s). r Dispenser Containment Float(s)and Chains. <br /> TNQN§,y?,_4L <br /> *If the facility contains more tanks or dispensers,copy this farm.Include Information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment Identified in this document was Inspected/serviced in accordance with the manufacturers'guidelines.Attached to <br /> this Certification Is information(e.g.manufacturers'cheddists)necessary to verify that this information is correct and a Plot Plan showing the layout of <br /> monitoring equipment.For any equipment capable of generating such reports,I have also attached a copy of the report; (check all that apply):rv—System set- <br /> up P7 Alarm history report <br /> Technician Name(print): Jarrod Cooke Signature: <br /> Certification No.: 5311523 License.No.: 743160 Class'A' <br /> Testing Company Name: Tanknology Phone No.: (800)800-4633 <br /> Testing Company Address: 11ODO N.MoPac Expressway Suite 500 Date of Testing/Servidng: 1/14/2014 <br /> Monitoring System Certification Page 1 of 3 12/07 <br />