My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2014
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1103
>
2300 - Underground Storage Tank Program
>
PR0232587
>
COMPLIANCE INFO_2011-2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2024 11:31:21 AM
Creation date
6/3/2020 9:58:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2014
RECORD_ID
PR0232587
PE
2361
FACILITY_ID
FA0004521
FACILITY_NAME
CHEVRON USA #201761*
STREET_NUMBER
1103
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
APN
21935038
CURRENT_STATUS
01
SITE_LOCATION
1103 S MAIN ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232587_1103 S MAIN_2011-2014.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
457
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
01/12/2015 13:53 1561 CHEVRON PAGE 05/06 <br /> San Joaquin County <br /> JAN 12 2015 1 ase East Hazelton n a enuel,HSbcktonnCalifornia s FEB 1 <br /> �. 'az0�6z3z 2015 <br /> -(200)488.3420 FM (209) 33 W9b.www. <br /> Jill VIRniv <br /> MEN 1 <br /> Fwirdy Mme. MFa4 A Edd mmmffla: tom: <br /> CHEVRON USA#201 761" 1103 S MAIN ST, MANTECA .tanua 12,2015 <br /> ttsm Fttamarka <br /> 7 CCR 2715 Designated operator did Wert inspect ail ruir�items ancuor the inspection reports nat completed. <br /> The designated operator failed to incl ude and/or review the alarm history pertaining to the February 14,2014 <br /> designated operator monthly Inspection report, during the monthly inspection,the designated operator shall review the <br /> alarm history far the previous month,check that each alarm was documented and responded to appropriately,and <br /> attach a copy of the alarm history with documentation taken In response to any alarms to the monthly report. Ensure <br /> that designated operators performing monthly inspections at this facility are including all of the required information on <br /> the reports. This is a repeat violation, Class II. <br /> 319 HSC 25291(a)Water In secondary containment not removed analyzed,and property dis <br /> Liquid was observed in the UDC 9/101 sump. if water could enter into the seconds containmdenttbp�ui natio <br /> p secondary y precipitation or <br /> infiltration, it must be removed and disposed of properly. The service technician removed tate observed liquid(less than <br /> 1 cup)utilizing absorbent pads and placed it in the onsite hazardous waste container pending disposal. Ensure that all <br /> sumps and annular spaces are maintained free of liquid. This is a Class it violation. This was corrected on site. <br /> 325 CCR 2635(b)Spin container failed to Contain a minimum capacity of five gallons. <br /> The 91-octane spill container failed when tested. All spill containers shall have a minimum capacity of five gallons and <br /> be capable of containing a spill or overfill until it is detected or cleaned up. The technician onsite cleaned the drain <br /> valve and retested the spill container with passing results.This is a minor violation.This was corrected on site. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Retum to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by February 11, 2015. <br /> Consent to perform the inspection,take photos and collect samples was given by Julie Kaderlik,the store <br /> manager. This facility's designated operator is Elli}ah pendergraft(iCC expiration date: ,lune 2,2016) . The <br /> service technician was Gilbert Garcia{ICC expiration date: July 11,2015),who had the following manufacturer's <br /> certifications: VR: March 13, 2015 and VMI (TLD-5000):March 25, 2015. <br /> Please be aware that as of January 1, 2014,facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System(CERS): UST Monitoring Site plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Owner/Operator:Written Agreement(if <br /> applicable), UST Letter from Chief Financial Officer, and Owner Statement of Designated UST Operator <br /> Compliance. <br /> HIS F CII SSU CT IhISPECT[ N 61 ANYTIME AT EHUS CU ENT QIIR Y T . <br /> Rectived By % ta: <br /> fP►lnMd rtxpector. esmpedor once <br /> ELENA MAN2O, REHS (209)953-7699 <br /> Pago 4 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.