Laserfiche WebLink
RECEIVED <br /> Appendix VI <br /> (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http://Www.swr4Ahc2.P2015 <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California ENVIRONMENTAL <br /> Authority Cited:Chapter 6.7,Health and Safety Code;Chapter 16,Division 3, 77tle 23,Califo�r�ia Cod u, ®�T <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for each monitoring <br /> system control panel by the technician who performs the work.A copy of this form must be provided to the tank system owner/operator.The <br /> owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: CHEVRON 201761 Bldg.No.: <br /> Site Address: 1103 S.MAIN ST.PERMIT NUMB.N-3315 City: MANTECA Zip: 95337 <br /> Facility Contact Person: MGR-MARIE Contact Phone No.: 209-825-0174 <br /> Make/Model of Monitoring System: Veeder Root TLS 350 Date of Testing/Servicing: 1/12/2015 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific equipment inspected/serviced: <br /> Tank ID: T1 Supreme-SUPREME Tank ID: T2 Regular 2-REGULAR <br /> r;In-Tank Gauging Probe. Model: MAG 8473 ( In-Tank Gauging Probe. Model: MAG 8473 <br /> r Annular Space or Vault Sensor. Model: 794390-409 r Annular Space or Vault Sensor. Model: 794390-409 <br /> W Piping Sump/Trench Sensor(s). Model: 794380-208 r Piping Sump/Trench Sensor(s). Model: 794380-208 <br /> We Fill Sump Sensor(s). Model: 794380-208 r: Fill Sump Sensor(s). Model: 794380-208 <br /> r Mechanical Line Leak Detector. Model: r Mechanical Line Leak Detector. Model: <br /> r,Electronic Line Leak Detector. Model: Veeder Root PLLD r Electronic Line Leak Detector. Model: Veeder Root PLLD <br /> rl Tank Overfill/High-Level Sensor.Model: FLAPPER r Tank Overfill/High-Level Sensor.Model: FLAPPER <br /> Other(specify equipment a and model in Section E on Page 2). r Other(specify equipment a and model in Section E on Pae 2). <br /> Tank ID: T3 Regular 1-REGULAR Tank ID: <br /> In-Tank Gauging Probe. Model: MAG 8473 r In-Tank Gauging Probe. Model: <br /> r'Annular Space or Vault Sensor. Model: 794390-109 r Annular Space or Vault Sensor. Model: <br /> r! Piping Sump/Trench Sensor(s). Model: 794380-208 r Piping Sump/Trench Sensor(s). Model: <br /> r Fill Sump Sensor(s). Model: 794380.208 r Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model r Mechanical Line Leak Detector. Model: <br /> r'Electronic Line Leak Detector. Model: Veeder Root PLLD r Electronic Line Leak Detector. Model: <br /> r Tank Overfill/High-Level Sensor.Model: FLAPPER Tank Overfill/High-Level Sensor.Model: <br /> Other(specify equipment a and model in Section E on Pae 2). Other(sNpecify equipment a and model in Section E on Pae 2). <br /> Dispenser 1/2 Dispenser 3/4 <br /> ID: ID: <br /> r Dispenser Containment Sensor(s).Model: 794380-208 r Dispenser Containment Sensor(s).Model: 794380-208 <br /> ri Shear Valve(s). r'Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser 5/6 Dispenser 7/8 <br /> ID: ID: <br /> r Dispenser Containment Sensor(s).Model: 794380-208 ri Dispenser Containment Sensor(s).Model: 794380-208 <br /> r Shear Valve(s). r Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). r Dispenser Containment Float(s)and Chain(s). <br /> Dispenser 9/10 Dispenser 11/12 <br /> ID: ID: <br /> r Dispenser Containment Sensor(s).Model: 794380-208 r Dispenser Containment Sensor(s).Model: 794380-208 <br /> r Shear Valve(s). r Shear Valve(s). <br /> Dispenser Containment Floats and Chain(s). r Dispenser Containment Floats and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines.Attached to <br /> this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct and a Plot Plan showing the layout of <br /> monitoring equipment.For any equipment capable of generating such reports,I have also attached a copy of the report;(check all that apply):r System set- <br /> up rAlarm history report <br /> Technician Name(print): Gilbert Garcia Signature: i <br /> Certification No.: 842816 License.No.: 743160 Class'A' <br /> Testing Company Name: Tanknology Phone No.: (800)800-4633 <br /> Testing Company Address: 11000 N.MoPac Expressway Suite 500 Date of Testing/Servicing: 1/12/2015 <br /> Monitoring System Certification Page 1 of 3 12/07 <br />