COMPLIANCE INFO_1995-2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
10842
>
2300 - Underground Storage Tank Program
>
PR0505615
>
COMPLIANCE INFO_1995-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2024 1:45:30 PM
Creation date
6/3/2020 9:58:50 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1995-2011
RECORD_ID
PR0505615
PE
2361
FACILITY_ID
FA0006898
FACILITY_NAME
RAMOS OIL-FRENCH CAMP
STREET_NUMBER
10842
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95231
APN
19333028
CURRENT_STATUS
01
SITE_LOCATION
10842 S HARLAN RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0505615_10842 S HARLAN_1995-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
471
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNIFIED PROGRAM CONSOLIDATED FOR, rp iE_, <br /> UNDERGROUND STORAGE TANK <br /> ills ,MONITORING PLAN-(Page 1 of 2) <br /> TYPE OF ACTION d 1.NEW PLAN 2.CHANGE OF INFORMATION 4901 <br /> PLAN TYPE ❑ 1.MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. e N ' i NNI NT HAT 490.2 <br /> (Check one item on) ) 2.THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(S) <br /> I. FACILITY INFORMATION <br /> FACILITY ID#(Agency Use Only) <br /> BUSINESS NAME(Same as FACILITY NAME) ���c+ C' 3. <br /> BUSINESS SITE ADDRESS d� S 32 103 CITY G f� �l�P err 3 104. <br /> H.EQUIPMENT TESTING AND PREVENTIVE MAINTENANCE, TJ <br /> Testing,preventive maintenance,and calibration of monitoring equipment(e.g.,sensors,probes,line leak detectors,etc.)must be performed at the frequency <br /> specified by the equipment manufacturers'instructions,or annually,whichever is more frequent,and that such work must be performed by qualified personnel. <br /> 23 CCR§2632,2634,2631,164 <br /> MONITORING EQUIPMENT IS SERVICED _ MANNUALLY El99.OTHER S eci 490-3 <br /> l. b <br /> ( p �')� 490.36 <br /> III.MONITORING LOCATIONS <br /> ❑1.NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN. 2.SITE PLOT PLAN/MAP PREVIOUSLY SUBMITTED. (23 CCR§2632, <br /> 2634)4904 <br /> IV.TANK MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S): <br /> ❑ 1.CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR(INTERSTITIAL)SPACE(S)OR SECONDARY CONTAINMENT 490-5 <br /> VAULT(S)WITH AUDIBLE AND VISUAL ALARMS (� 2�,CCR§2632,2634) <br /> SECONDARY CONTAINMENT IS: ❑ a.DRY b.LIQUID FILLED ❑ c.PRESSURIZED ❑d.UNDER VACUUM 490-6 <br /> ------------------------------------ <br /> ------------------------------------------------------------------ - <br /> = 490-7. <br /> ------'-----------.-_---__._.----------'-------'--_----- <br /> PANEL MANUFACTURER: c�� - - MODEL#: / 3 <br /> LEAK SENSOR MANUFACTURER: �-Q 490 9 ; MODEL#(S): /Sj`� �.G Z - 0.900.0 <br /> ❑ 2.AUTOMATIC TANK GAUGING(ATG)SYSTEM USED TO MONITOR SINGLE WALL TANK(S).(23 CCR§2643) 490-11 <br /> PANEL MANUFACTURER: 490-1 MODEL#: 490.13 <br /> -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- --- <br /> .� 490.14 499 0.15 <br /> -- _ <br /> IN-TANK PROBE MANUFACTURER: MODEL#(S)- <br /> LEAK TEST FREQUENCY: a.CONTINUOUS ❑ b.DAILY/NIGHTLY ❑ c.WEEKLY 490.16 <br /> 490-17 <br /> -- - --- - -- - -�d_MONTHLY El- -- --- -e.OTf LER(Speclf�):-------- <br /> ----------------------------------490-17 <br /> 490-I8 <br /> PROGRAMMED TESTS: F-1 a.0.1 g.p.h. b 0.2 g.p.h. El c.OTHER(Specify): 490-19 <br /> ❑ 3.MONTHLY STATISTICAL INVENTORY RECONCILIATION(23 CCR§2646.1): 490-20 <br /> ❑ 4.WEEKLY MANUAL TANK GAUGING(MTG)(23 CCR§2645). TESTING PERIOD: Ela.36 HOURS [:1b.60 HOURS 490-22 <br /> El5.TANK INTEGRITY TESTING(23 CCR§2643.1): 490-23 <br /> 440-24 <br /> TEST FREQUENCY: ❑ a.ANNUALLY b b.BIENNIALLY ❑ c.OTHER(Specify): 490-25 <br /> 490-26 <br /> ❑99.OTHER (Specify): - 490-27 <br /> V.PIPE MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S)(Check all that apply) <br /> ❑ 1.CONTINUOUS MONITORING OF PIPE/PIPING SUMP(S)AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE AND 490-28 <br /> VISUAL ALARMS. (23 CCR§2636) <br /> SECONDARY CONTAINMENT IS: a.DRY ❑b.LIQUID FILLED 0c.PRESSURIZED ❑d.UNDER VACUUM 490-29 <br /> 490-3C490-3t <br /> PANEL MANUFACTURER: - �_(� _ _ i MODEL#: l la -- <br /> c <br /> 490-32 i - 490-33 <br /> I - LEAK SENSOR-MANUFACTURER_ 1_---_� ; MODEL.#(S):- L 490-34 <br /> PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(i.e.,TURBINE)SHUTDOWN. .1� I a YES ❑b.NO <br /> FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. .YES ❑b.NO 490-35 <br /> ❑ 2.MECHANICAL.LINE LEAK DETECTOR(MLLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS AND RESTRICTS OR SHUTS OFF <br /> -PRODUCT FLOW WHEN_A LEAK IS DETECTED_(Z3 CCR k2636)__---_--_ 490-36 <br /> MLLD MANUFACTURER(S): 490-37 MODEL#(S): 490-38 <br /> ❑ 3.ELECTRONIC LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS (23 CCR§2636) 490.39 <br /> ------------ -- - - ---- --- -------------------- - - --,----- - - - -- -- -- <br /> ------------- <br /> a9o4o ; 0.9041 <br /> --ELLD MANUFACTURER(S) -- - ------------- ------------------------- --- --MODEL#(S)_ ----------------------------------------- <br /> PROGRAMMED IN LINE LEAK TEST: ❑ 1.MINIMUM MONTHLY 0.2 g.p.h. ❑ 2.MINIMUM ANNUAL 0.1 g.p.h. 49042 <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑a.YES ❑b.NO 49043 <br /> ELLD FAILURE/DISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑a.YES ❑b.NO 49044 <br /> 4.PIPE INTEGRITY T STING 49045 <br /> TEST FREQUENCY�K a.ANNUALLY ❑ b.EVERY 3 YEARS ❑ c.OTHER(Specify) 4904649047 <br /> ❑ 5.VISUAL PIPE MONITORING. 490.48 <br /> FREQUENCY ❑ a.DAILY ❑ b.WEEKLY ❑c.MIN.MONTHLY&EACH TIME SYSTEM OPERATED- 490-49 <br /> °Allowed for monitorine of unburied emer enc•generator fuel piping only per HSC§25281.5(b)(3 <br /> ❑ 6.SUCTION PIPING MEETS EXEMPTION CRITERIA 123 CCR§2636(a)(3)1. 490-50 <br /> ❑ 7.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20,CHAPTER 6.7 IS CONNECTED TO THE TANK SYSTEM <br /> j 490-51 49052 <br /> ❑ 99 OTHER(Specify) <br /> UPCF LIST-D(12/2007)1/4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.