My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1995-2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
10842
>
2300 - Underground Storage Tank Program
>
PR0505615
>
COMPLIANCE INFO_1995-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2024 1:45:30 PM
Creation date
6/3/2020 9:58:50 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1995-2011
RECORD_ID
PR0505615
PE
2361
FACILITY_ID
FA0006898
FACILITY_NAME
RAMOS OIL-FRENCH CAMP
STREET_NUMBER
10842
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95231
APN
19333028
CURRENT_STATUS
01
SITE_LOCATION
10842 S HARLAN RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0505615_10842 S HARLAN_1995-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
471
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
` * FIED PROGRAM CONSOLIDATED FORMTANK: TA0505616 <br /> bE <br /> b 7- 4�PR#: PR0505615 <br /> , fAC#: FA0006898 <br /> UNDERGROUND STORAGE TANKS -TANK PAUyv <br /> VI.PIPING CONSTRUCTION(Chink all that apply) Page 3 of 3 <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE W1.PRESSURE ❑ 2.SUCTION ❑ 3.GRAVITY 458 ❑ 1.PRESSURE ❑ 2.SUCTION ❑3.GRAVITY 459 <br /> CONSTRUCTION ❑1.SINGLE WALL ❑3.LINED TRENCH ❑ 99.OTHER 460 ❑ 1.SINGLE WALL ❑ 95.UNKNOWN 462 <br /> 2.DOU4E WALL 095.UNKNOWN ❑ 2.DOUBLE WALL ❑99.OTHER <br /> MANUFACTURE ko 5 m OL, 461 MANUFACTURER 463 <br /> ❑ 1.BARE STEEL ❑6.FRP COMPATIBLE w/100%METHANOL ❑ 1.BARE STEEL ❑6.FRP COMPATIBLE V 100%METHANOL <br /> ❑ 2.STAINLESS STEEL ❑7.GALVANIZED STEEL ❑ 2.STAINLESS STEEL ❑7.GALVANIZED STEEL <br /> ❑ PLASTIC COMPATIBLE W/CONTENTS ❑ 95.UNKNOWN ❑ PLASTIC COMPATIBLE W/CONTENTS ❑ 95.UNKNOWN <br /> A4.FIBERGLASS ❑ 8.FLEXIBLE(HDPE) ❑ 99.OTHER ❑ 4.FIBERGLASS ❑ 8.FLEXIBLE(HDPE) ❑ 99.OTHER <br /> ❑ 5.STEEL W/COATING ❑ 9.CATHODIC PROTECTION 464 ❑ 5.STEEL W/COATING ❑ 9.CATHODIC PROTECTION <br /> 465 <br /> VII.PIPING LEAK DETECTION(Cheek all that apply)(A description of the monitoring program shall be submitted to the local agency.) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING 466 SINGLE WALL PIPING 467 <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> ❑ 1.ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF ❑ 1.ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF <br /> FOR LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND FOR LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND <br /> VISUAL ALARMS. VISUAL ALARMS. <br /> ❑ 2.MONTHLY 0.2 GPH TEST <br /> ❑ 3.ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 2•MONTHLY 0.2 GPH TEST E] 3.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 4.DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS CONVENTIONAL SUCTION SYSTEMS(Check all that apply) <br /> ❑ 5.DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIEAL PIPING ❑ 5.DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> INTEGRITY TEST(0.1 GPH) ❑ 6.TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SAFE SUCTION SYSTEMS(NO VALUES IN BELOW GROUNDPIPING): SAFE SUCTION SYSTEMS(NO VALUES IN BELOW GROUNDPIPING): <br /> ❑7.SELF MONITORING <br /> ❑ 7.SELF MONITORING <br /> GRAVITY FLOW <br /> ❑ 9.BIENNIAL INTEGRITY TEST(0.1)GPH GRAVITY FLOW(Check all that apply): <br /> ❑ 8.DAILY VISUAL MONITORING <br /> ❑ 9.BIENNIAL INTEGRITY TEST(0.1)GPH <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> 10.CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL 10.CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL <br /> ALARMS AND(Cheek one) ALARMS AND(Chock one) <br /> •a.AUTO PUMP SHUT OFF WHEN A LEAK OCCURS ❑ a.AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> Ph (fib.AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND-'STM ❑ b.AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM <br /> T DISCONNECTION -11'yU o DISCONNECTION <br /> / ❑ c.NO AUTO PUMP SHUTOFF ❑ C.NO AUTO PUMP SHUT OFF <br /> I?4111.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITH FLOW SHUT OFF OR ❑ <br /> RESTRICTION 11 AUTOMATIC LEAK DETECTOR <br /> T <br /> ❑ 12.ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 12.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> SUCTION/GRAVITY SYSTEM SUCTION/GRAVITY SYSTEM <br /> ❑ 13.CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 13.CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check all that apply) EMERGENCY GENERATORS ONLY(Cheek all that apply) <br /> ❑ 14.CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF ❑ 14.CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF <br /> AUDIBLE AND VISUAL ALARMS AUDIBLE AND VISUAL ALARMS <br /> ❑ 15.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW ❑ 15.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW <br /> SHUT OFF OR RESTRICTION SHUT OFF OR RESTRICTION <br /> ❑ 16.ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 16.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 17.DAILY VISUAL CHECK ❑ 17.DAILY VISUAL CHECK <br /> VIII.DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT ❑ 1.FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE ❑4.DAILY VISUAL CHECK <br /> DATE INSTALLED 468 2 CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 5.TRENCH LINER/MONITORING <br /> ❑ 3.CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR ❑ 6.NONE <br /> DISPENSER+AUDIBLE AND VISUAL ALARMS 469 <br /> IX.OWNER/OPERATOR SIGNATURE <br /> I certify that the' provided herein is true a a e bat of my k-lodge. <br /> SIGNATURE O WNER/OPERATOR DATE 470 <br /> LIMA-VA 0 - a o <br /> NAM R/OPE TOR(pi TITLE OF OWNER/OPERATOR <br /> /) N11 471 A / 472 <br /> Permit Number(For lohtfmc only) 473 Permit Approved(For local use only) 474 Permit Expiration to(For local use only) 475 <br /> PT0008177 EE0003804 12/31/2002 <br /> UPCF(12/99 revised) <br />
The URL can be used to link to this page
Your browser does not support the video tag.