Laserfiche WebLink
-0 0 <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209) 468-3420 Fax:(209)468-3433 Web:www.sjgov.org//ehd <br /> Underground Storage;Tank Rragram <br /> Inspection Report <br /> Facility Name: Facility Address: Date: <br /> RAMOS OIL-FRENCH CAMP 10842 S HARLAN RD, FRENCH CAMP October 27, 2016 <br /> K <br /> SUMMARY OFNIPLATIONS <br /> (CF ASS 1,CLASS Its or MINOR,=_Notice to Comply) <br /> Item # Remarks <br /> 119 HSC 25299 Documents were falsified or misrepresented. <br /> During the inspection it was noted by the inspector several designated monthly inspection reports looked almost <br /> identical to one another. The writing was in red and all of the same fill in the blank areas and "corrections"were <br /> noted. The alarm histories that were attached did not have a date on the top of them. One of the reports from April <br /> should have had an alarm noted and did not. Instead it was noted there had not been any alarms for the previous <br /> month. When the designated operator, Steven Richardson was asked if he had completed the reports today <br /> (October 27, 2016) he said yes. He said the reports had been completed but are now missing. <br /> Immediately prepare a written statement and submit it to the EHD indicating how this practice will be prevented in <br /> the future and whats steps will be taken to ensure compliance. <br /> This is a Class I violation. <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report. <br /> An inspection was done on October 30, 2014 and October 29, 2015 and an inspection report was issued identifying <br /> information to be submitted to bring this site into compliance. This information was required to be submitted by Nov <br /> 30, 2014 and December 3, 2015 . This information has not been received resulting in a non-compliant status for <br /> this facility. An operator that receives an inspection report shall have 30 days to submit a written response that <br /> includes a statement documenting corrective actions taken or proposing corrective actions which will be taken. <br /> Ensure that a written response documenting corrective actions taken or proposed is submitted within 30 days of <br /> receiving an inspection report. Immediately submit written responses for the above listed inspections. <br /> This is a repeat violation, Class Il. <br /> 201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions. <br /> An alarm was seen on the alarm history print out from April 27, 2016. The alarm was for the L-2 and L-3 sensors. <br /> There was no maintenance record or notation about this alarm on site. These records must be maintained for a <br /> minimum of 3 years. Immediately submit a maintenance record and/or a statement indicating what caused the <br /> alarms and what action was taken to correct them. <br /> This is a Class II violation. <br /> 203 CCR 2712(b) Failed to maintain records of monitoring, repair, lining, and upgrades on site. <br /> Maintenance and monitoring records for the last three years were not found on site. Monitoring system certification <br /> test results for 2013 were not found on site. These records shall be maintained on site for at least three years. <br /> Monitoring records include: (1) date and time of all monitoring or sampling; (2) monitoring equipment calibration and <br /> maintenance records; (3) results of any visual observations; (4) results of sample analysis performed a lab or in the <br /> field; (5) logs of all readings of gauges or other monitoring equipment, ground water elevations, or other test results; <br /> (6) results of inventory readings and reconciliations. Immediately locate and maintain all maintenance and <br /> monitoring records for the last three years on site and submit copies to the EHD. <br /> This is a repeat violation (which is currently still open)from 2015. <br /> This is a repeat violation, Class II. <br /> FA0006898 PRO605615 SCO01 10/27/2016 <br /> EHD 23-01 Rev.09/22/16 Page 5 of 7 Underground Storage Tank Program OIR <br />