My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
10842
>
2300 - Underground Storage Tank Program
>
PR0505615
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/20/2021 11:43:46 AM
Creation date
6/3/2020 9:58:54 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0505615
PE
2361
FACILITY_ID
FA0006898
FACILITY_NAME
RAMOS OIL-FRENCH CAMP
STREET_NUMBER
10842
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95231
APN
19333028
CURRENT_STATUS
01
SITE_LOCATION
10842 S HARLAN RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0505615_10842 S HARLAN_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
516
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 - W <br /> Telephone:(209)468-3420 Fax:(209) 468-3433 Web:www.sjgov.org/ehd ' Z-1 5- <br /> Facility Name: Facility Address: Date: <br /> RAMOS OIL-FRENCH CAMP 10842 S HARLAN RD, FRENCH CAMP October 29, 2015 <br /> Item# Remarks <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted. <br /> Complete financial responsibility documents have not been submitted to the EHD. The date is missing on the <br /> Certification of Financial Responsibility. Current financial responsibility documents are required to be submitted <br /> annually. Immediately log into the California Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/, <br /> and upload the required documents. <br /> This is a repeat violation, Class II. <br /> 104 CCR 2711 UST Operating Permit Application for Facility and Tank information not submitted or current. <br /> The UST Tank Information form for the diesel tank(TA0505616) is not current in CERS. Primary containment tank <br /> construction, piping construction and piping primary containment, vent primary and secondary containment <br /> construction, vapor recovery primary and secondary containment construction, riser pipe primary and secondary <br /> containment construction, vent piping transition sumps construction, and corrosion protection were not provided or <br /> were incorrect. Also the applicant's name on the UST Tank Information form is outdated. Any change of information <br /> must be updated in CERS within 30 days of the changes. Immediately log into CERS, update the required <br /> information, and submit for review by the EHD. <br /> This is a Class II violation. <br /> 106 CCR 2632 Monitoring and response plans not current or approved by the EHD. <br /> The monitoring plan is not current and/or not approved by the EHD. The monitor panel manufacturer, monitor panel <br /> model, leak sensor manufacturer, leak sensor model number, continuous monitoring of piping secondary <br /> containment, pipeline integrity testing and frequency, UDC monitoring, UDC panel manufacturer and model number, <br /> UDC leak sensor and model and UDC construction were incomplete or inaccurate. The monitoring system at the site <br /> was changed from an Incon to a Veeder Root monitoring panel and sensors in October 2012. The monitoring plan <br /> must be uploaded to the California Environmental Reporting System (CERS). Immediately log into CERS, make the <br /> necessary changes, and submit for review by the EHD. <br /> This is a minor violation. <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br /> An accurate UST Monitoring Site Plan was not submitted. Missing are the UDC sensors, annular sensor, and fill <br /> sump sensor. A site plan must be submitted identifying the locations where monitoring will be performed. <br /> Immediately log into the California Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/and upload <br /> a copy of the UST Monitoring Site Plan. <br /> This is a minor violation. <br /> Received by Inspector: Phone: Date: <br /> (initial): ' VICKI MCCARTNEY, Senior REHS (209)468-9852 10/29/2015 <br /> Page 4 of 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.