My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
10842
>
2300 - Underground Storage Tank Program
>
PR0505615
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/20/2021 11:43:46 AM
Creation date
6/3/2020 9:58:54 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0505615
PE
2361
FACILITY_ID
FA0006898
FACILITY_NAME
RAMOS OIL-FRENCH CAMP
STREET_NUMBER
10842
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95231
APN
19333028
CURRENT_STATUS
01
SITE_LOCATION
10842 S HARLAN RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0505615_10842 S HARLAN_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
516
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue,Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.oLg/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Phone: Date: <br /> `1 �-`l i--F PRC %'_'o ' 1 016) i71 211'71) <br /> Facility Address: CERS ID: <br /> 101842 S Hl, RL,=,N RL) '4-1\ ,N��Ji ;ANIP CA :i5231 <br /> Inspection Contact: Title: —]—Fho—n-;7 <br /> Inspection Type: Program: <br /> ROUTINE INSPECT luN Op&,itinj Poimit 2361 - U1,I' I-A(,'ILIFY <br /> Consent For: Consent Given By: <br /> X Inspection X< Photos Sam2les Joy Kachidoiiaii. LHS Manages <br /> Service Technician Onsite: Exp.Date: Designated Operator: Exp.Date: <br /> "Ohn Puunlal 1 01!26,2013 Stephanie Murphy "J <br /> Ls 2 <br /> Service Technician Manufacturer's Training: <br /> VIM1 12.30 13 'Veeder Root. 07 19119 <br /> CCR-California Code of Regulations HSC=Health and Safety Code CFR=Code of Federal Regulations <br /> V=Violation R=Repeat violation COS=Corrected on site during onspecitof <br /> File Review <br /> 101 HSC 25284 No permit to operate V R =1- <br /> 102 HSC 25284(a)(3) No written agreement between tank owner and tank operator to monitor the tank system =V R COS <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted =V R COS <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current V P COS <br /> 105 CCR 2632(d)(1) Failed to have an approved UST monitoring plan =V R COS <br /> 106 CCR 2632(d)(2) Failed to have an approved UST response plan =V R COS <br /> 107 CCR 2632(d)(1)(C) Plot planisite map not submitted or failed to completely show where monitoring is performed ■V a R COS <br /> 108 CCR 2637(f),2638(e) Faded to notify the EHD 48 hours prior to conducting testing V R COS <br /> 109 CCR 2637 Faded to test secondary containment V R COS <br /> 110 CCR 2637(e) Failed to submit secondary containment test report within 30 days V R COS <br /> Ill CCR 2638(a) Failed to test monitoring and leak detection equipment annually V R COS <br /> 112 HSC 25284.2 Failed to test spill containers annually V R COS <br /> 113 CCR 2638(d) Failed to submit monitoring system certification test report within 30 days V R OS <br /> 114 CCR 2636(f) Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down V R COS <br /> 115 CCR 2715(a) Failed to inform the EHD of designated operator identification or change within 30 days V R COS <br /> 116 CCR 2715 Designated operator,service tech or installer did not possess current ICC certification V R COS <br /> 117 CCR 2663 Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after V R Ck-)c <br /> 118 CCR 2663 Failed to submit tank lining certification within 30 days or to conduct proper tests V R COS <br /> 119 HSC 25299 Documents were falsified or misrepresented V R <br /> 120 CCR 2635(d) Faded to submit UST Certification of Installation/Modification V R (7(1", <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report a V a R COF <br /> 122 CCR 26310) Failure to submit UST system component statement of compatibility for substance stored V R CO� <br /> On Site Records <br /> 201 CCR 2712(b) Failed to maintain alerm logs and/or records of follow up actions a V a R rnc <br /> 202 CCR 2712(b) Failed to maintain cathodic protection test records on site for at least 6 112 years V R ((0)ir <br /> 203 CCR 2712(b) Failed to maintain records of monitoring,repair,lining,and upgrades on site V P cn!; <br /> FA000689e PROS is scone. <br /> EHD 23-01 Rev O/22/16 page I Of 5 Underground Storage Tank PfN,,,, (,r- <br />
The URL can be used to link to this page
Your browser does not support the video tag.