My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
10842
>
2300 - Underground Storage Tank Program
>
PR0505615
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/20/2021 11:43:46 AM
Creation date
6/3/2020 9:58:54 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0505615
PE
2361
FACILITY_ID
FA0006898
FACILITY_NAME
RAMOS OIL-FRENCH CAMP
STREET_NUMBER
10842
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95231
APN
19333028
CURRENT_STATUS
01
SITE_LOCATION
10842 S HARLAN RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0505615_10842 S HARLAN_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
516
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov or-q/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> e <br /> S 0 N,,'� 1 10 A, j;'I,,I A r I I�i) I i f i I Z' <br /> On Site Records <br /> 204 CCR (1) -- Current monitoring plan approved by the EHD not found on site a V a R COS <br /> 205 CCR 2712(.) Failure to have an approved LIST response plan available onsite V R COS <br /> 206 CCR 2712 Failure to comply with UST operating permit conditions V R COS <br /> 207 HSC 25294 Failed to record unauthorized release from primary containment V R COS <br /> 208 CCR 2650(e) Failed to notify the EHD of a reportable unauthorized release V -R COS <br /> 209 CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed •V a R COS <br /> 210 CCR 2715(e) Designated operator monthly inspection reports not maintained on site for at least 12 months •V a R COS <br /> 211 CCR 2715(f) Designated operator employee training not performed or log not kept V R -COS <br /> 212 CCR 2715(f)(2) Unstaffed facility failed to have or implement a training program approved by the EHD =V R COS <br /> 213 HSC 25281-5(b)(2) Unburied fuel piping at marinas not visually inspected at least daily or log not kept V R -COS <br /> 214 HSC 25281 5(b)(3) Unburied emergency generator fuel piping not visually inspected at least monthly or log kept =v R COS <br /> UST System Observations <br /> 301 HSC 252921 LIST system is not operated to prevent unauthorized release,including spills and overfills V R COS <br /> 302 HSC 25291(b) LIST system incapable of detecting leak from primary into secondary containment(pre-Jul 2003) V R COS <br /> 303 HSC 25290,2(d) Monitoring system not maintained to detect entry into secondary containment(Jul 2003-Jun 2004) V R COS <br /> 304 1 HSC 25290 1(d) Monitoring system not maintained to detect entry into secondary containment(after Jul 2004) V =R COS <br /> 305 HSC 25290.1(a) VPH monitoring of the interstitial spaces of the LIST system is not maintained V R COS <br /> 306 CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity V R COS <br /> 307 CCR 2632(c) Monitoring system of the interstitial space of a double walled system not maintained V R COS <br /> 308 CCR 2636(f) Failed to maintain a continuous monitoring system that activates an audible and visual alarm v R COS <br /> 309 CCR 2636(f)(1) Monitoring in sump I UDC failed to activate an audible and visual alarm or stop the flow product V R COS <br /> 310 CCR 2636(f)(5) Failure to meet monitoring requirements in lieu of annual line tightness test V R COS <br /> 311 CCR 2638(a),2641 Q) Failed to property program or operate teak detection equipment V R COS <br /> 312 CCR 2638(f) Failed to affix a tag sticker on monitoring equipment certified,repaired,or replaced V R COS <br /> 313 HSC 252901,25290.2. Failure to construct,operate,and maintain primary containment as product-tight v R COS <br /> 25291 <br /> 314 HSC 25290.1,25290.2, Failed to have secondary containment or secondary containment not fight v R COS <br /> 25291 <br /> 315 HSC 25291(e) Water in secondary containment not removed,analyzed,and properly disposed of(pre-Jul 2003) V R COS <br /> 316 HSC 25290,1(0), Secondary containment not constructed to prevent water intrusion(after Jul 2003) V R COS <br /> 25290.2(c3) <br /> 317 CCR 2636(f)(2) Line leak detector not installed V R COS <br /> 318 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi v R COS <br /> 319 CCR 2635(b) No spill bucket,failed to contain five gallons,or failed to provide a means to keep it empty V R COS <br /> 320 CCR 2635(b)(2) Overfill prevention system not present or failed to meet overfill requirements V R COS <br /> 321 CCR 2635(b)(2) overfill prevention was overridden V R COS, <br /> FA 98 PRO505615 SC001 1012112C,- <br /> EHD 23-01 Rev 09!22116 Pap 2 of$ Und"gMund Storage rank Prinra,,(No <br />
The URL can be used to link to this page
Your browser does not support the video tag.