Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.siaov.ora/ehd <br /> Undergrclund Storage Tank Program Report <br /> Facility Name: Facility Address: Date: <br /> RAMOS OIL-FRENCH CAMP 10842 S HARLAN RD, FRENCH CAMP October 25, 2017 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS 1,CLASS 11,orIV1INOR-Notice to Comply- <br /> Item# Remarks <br /> 201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions. <br /> Maintenance and monitoring records for the last three years were not found on site. <br /> The 2016 annual spill bucket and line leak detector test results were not available for review during the time of <br /> inspection. <br /> On the July 2017 monthly designated operator(DO) report,the DO mentioned that the filter piping was leaking <br /> which was triggering an L7: master dispenser 3-4 alarm. The DO noted that a'Ramos Mechanic"came out to the <br /> site to fix the leak.There were no work orders or logs found on site documenting the repair. Immediately submit <br /> documents showing how the leak was fixed and what was done with the waste to the EHD. <br /> On October 20,2017,there was an L2: diesel stp sump fuel alarm that occurred. According to Joy Kachadorian, <br /> Ramos should have come to the site to investigate the alarm. There were no records on site indicating how the <br /> alarm was handled. Immediately submit documents to EHD showing how the alarm was handled. <br /> These records shall be maintained on site for at least three years. Monitoring records include: (1)date and time of <br /> all monitoring or sampling; (2)monitoring equipment calibration and maintenance records; (3)results of any visual <br /> observations; (4)results of sample analysis performed a lab or in the field; (5)logs of all readings of gauges or other <br /> monitoring equipment, ground water elevations, or other test results; (6)results of inventory readings and <br /> reconciliations. Immediately locate and maintain the above mentioned maintenance records and send them to the <br /> EHD. <br /> This is a repeat violation, Class ll. <br /> 204 CCR 2712(1)Current monitoring plan approved by the EHD not found on site. <br /> An approved copy of the monitoring plans were not available for inspection. A copy of these plans shall be <br /> accessible on site at all times. Immediately locate and retain a copy on site. <br /> This is a repeat violation, Class ll. <br /> 209 CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator failed to review all of the liquid sensor alarms from the alarm history on the 5/31/2017 <br /> designated operator monthly inspection report and failed to check that they were responded to appropriately. <br /> The L8 satellite dispenser pan 4-5 alarm was missing from the attached print out. During the monthly inspection,the <br /> designated <br /> operator shall review the alarm history for the previous month, check that each alarm was documented and <br /> responded to appropriately, and attach a copy of the alarm history with documentation taken in response to any <br /> alarms to the monthly report. Ensure that designated operators performing monthly inspections at this facility are <br /> including all of the required information on the reports <br /> This is a repeat violation, Class ll. <br /> FA0006898 PR0505615 SCO01 10/25/2017 <br /> EHD 23-01 Rev.09/22/16 Page 4 of 5 Underground Storage Tank Program OIR <br />