My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
437
>
2300 - Underground Storage Tank Program
>
PR0506406
>
COMPLIANCE INFO_2009-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/17/2023 3:32:05 PM
Creation date
6/3/2020 9:58:56 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2018
RECORD_ID
PR0506406
PE
2361
FACILITY_ID
FA0002313
FACILITY_NAME
WILSON WAY CHEVRON
STREET_NUMBER
437
Direction
N
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
15113052
CURRENT_STATUS
01
SITE_LOCATION
437 N WILSON WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0506406_437 N WILSON_2009-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
439
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br /> SWRCB,January 2002 <br /> Pale of_. <br /> L <br /> Faciliv°is Fill Riser Conti ent S s <br /> Fill Riser Containment Sumps are Present,but were Not T ed C <br /> Test!method Developed By: w S '�Ia:aufa , . C Ila � strydard Professional Engin <br /> eer <br /> C Other(Specify) <br /> Test Method Used: C Pressure n Vacuum Hydrostatic <br /> C Other(Specify) <br /> Test Equipment Used: INC5N TS—STS <br /> 0.0001 <br /> Fal!aurla ,#.,� <br /> St��z ��yiarnL' 4;� 42 <br /> Fiei�ht from T le Top to Top o£ ®®e <br /> off <br /> Idi hest Pi ing Penetration: <br /> Height from Tank'Top to Lowest 2 519 2 7'® � <br /> EIe c t rcat Pene mation- <br /> Condition of sump prior to <br /> testing: Clean Clcan Clcan <br /> Portion ofS Tested 27,, 28'1 <br /> S :lateral. —FR—P FRP <br /> Wait time between applying <br /> Pressure/vacuum/water and 1 0 m i n. 1 O m i n. <br /> stafte test: <br /> Test Start Time: 10 :4 am 10 : am <br /> Initial eadin Rr : 3.7827" .6063" <br /> Test End Time: <br /> Final Reading(R,)- 3.7825" . 6062" <br /> Test Duration: 15min. 15min. <br /> e i Reading SRI ; 0.0 0 " .0 0 01 " <br /> Pass/Fail Threshold or Criteria.: t 0.0 " ±0.002" <br /> "est Result: Pass Fall 1 3 Pass C Fail Pass 0 Fail C PUS C Fail <br /> Is there a sensor in the Sump? Byes C No R Yes 0 No 1 11 Yes C No C Yes C No <br /> Does the sensor alarm when Yes C No ❑NA <br /> either Product water is es C No CNA C Yes C No C NA 11 Yes C No CNA <br /> Was sensor removed for testing? Yes C No C NA qS Yes C No CNA C Yes C No C NA C Yes C No CNA <br /> Was sensor properly replaced �S Yes ®No C N <br /> -- <br /> venfied functional after testing? RLYes C No a N.A. 1es u No C NA E Yes 0 No C NA <br /> CO <br /> S m(incl or �ti�rt or:re airs rna�'c rior tat tin , araa'rcc�rrrre d fvllra�vmt� for aile�'tests <br /> OCT 20 <br /> ' f <br />
The URL can be used to link to this page