COMPLIANCE INFO_2009-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
437
>
2300 - Underground Storage Tank Program
>
PR0506406
>
COMPLIANCE INFO_2009-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/17/2023 3:32:05 PM
Creation date
6/3/2020 9:58:56 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2018
RECORD_ID
PR0506406
PE
2361
FACILITY_ID
FA0002313
FACILITY_NAME
WILSON WAY CHEVRON
STREET_NUMBER
437
Direction
N
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
15113052
CURRENT_STATUS
01
SITE_LOCATION
437 N WILSON WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0506406_437 N WILSON_2009-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
439
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page of <br /> 8. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sums ❑ <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ <br /> Test Method Developed By: ❑ Sump Manufacturer I]Industry Standard X Professional Engineer <br /> ❑Other(Specify) <br /> Test Method Used: '-1 Pressure ❑Vacuum X Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: Caldwell Level Change Indicator Equipment Resolution: .002 <br /> Fill Sump#1-87 Fill Sump#2-91 Fill Sump# Fill Sump# <br /> Sump Diameter: 42" 42" <br /> Sump Depth: 57 ''/2" 56 '/2" <br /> Height from Tank Top to Top of No Piping No Piping <br /> Highest Piping Penetration: Penetrations Penetrations <br /> Height from Tank Top to Lowest 21" 21" <br /> Electrical Penetration: ,. <br /> Condition of sump prior to Dry Dry <br /> testing: <br /> Portion of Sump Tested Water Level 25" Water Level 25" <br /> Sump Material: Fiberglass Fiberglass <br /> Wait time between applying 5 Minutes 5 Minutes <br /> water and starting test: <br /> Test Start Time: 8:57 9:47 <br /> Initial Reading(R,): .001 .001 <br /> Test End Time: 9:27 10:17 <br /> Final Reading(RF): .001 .001 <br /> Test Duration: 30 Minutes 30 Minutes <br /> Chane in Reading (RF—RI): 0 0 <br /> Pass/Fail Threshold or Criteria: .005/30 Minutes .005/30 Minutes <br /> Test Result: Pass Pass <br /> Is there a sensor in the sump? Yes Yes <br /> Does the sensor alarm when <br /> either product or water is Yes Yes <br /> detected? <br /> Was sensor removed for testing? Yes Yes <br /> Was sensor properly replaced and Yes Yes <br /> verified functional after testing?____] <br /> Comments— (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />