Laserfiche WebLink
t❑ <br />• <br />,rFw FIBERGLASS <br />2.3.1 Preparation <br />When installing a secondary contain- <br />ment system from Smith Fiberglass <br />Products, some preparation is neces- <br />sary if the closest possible separation <br />of lines is required. To minimize the <br />overall change in elevation when in- <br />stalling a containment crossover, it is <br />• i o <br />necessary to shorten one leg of the <br />450 containment elbow and the side <br />outlet run of the containment tee. <br />Refer to Table 2.3.1 forthemaximum <br />length that can be removed and for <br />the minimum nipple length of both <br />product piping and secondary con- <br />tainment piping. <br />To prevent interference of the pipe- <br />lines, do not locate two containment <br />fittings closer than shown in Table <br />2.3.2, Figure 2.3.1. <br />TABLE 2.3.1 <br />CONTAINMENT CROSSOVER INFORMATION <br />"' Actual length of the product nipple will vary slightly because of different insertion lengths due to variations in tapers. <br />TABLE 2.3.2 <br />PIPE SEPARATION DISTANCES <br />Containment <br />Remove from <br />Remove from <br />Containment <br />45° Crossover <br />Side Run— <br />Product'" <br />Containment <br />Pipe Size <br />Elbow <br />Tee <br />Nipple Size <br />Nipple Size <br />(in.) (mm) <br />(Max. in.) (Max. mm) <br />(Max. in.) (Max. mm) <br />(Min. in.) (Min. mm) <br />(Min. in.) (Min. mm) <br />3 75 <br />1.25 32 <br />1.50 38 <br />2 x 8 50 x 200 <br />3 x 6 75 x 150 <br />4 100 <br />2.00 51 <br />1.63 41 <br />3 x 8 75 x 200 <br />4 x 6 100x 150 <br />6 150 <br />1.25 32 <br />1.00 25' <br />4 x 10 100 x 250' <br />6 x 8 150 x 200 <br />"' Actual length of the product nipple will vary slightly because of different insertion lengths due to variations in tapers. <br />TABLE 2.3.2 <br />PIPE SEPARATION DISTANCES <br />Containment <br />Pipe <br />A <br />B <br />C <br />D <br />E <br />(in.) <br />(in.) <br />(in.) <br />(il <br />(in.) <br />(in.) <br />3 <br />7.5 <br />10.6 <br />6.5 <br />10 <br />14.5 <br />4 <br />8.5 <br />12 <br />7.5 <br />1216.5 <br />419 <br />6 <br />10.65 <br />15 <br />8 <br />14.7 <br />22 <br />Containment <br />Pipe <br />A <br />B <br />C <br />D <br />E <br />(mm) <br />(mm) <br />(mm) <br />(mm) <br />(mm} <br />(mm) <br />75' <br />191 <br />269 <br />165 <br />254- <br />368, <br />100 <br />216 <br />305 <br />191 <br />305' <br />419 <br />150 <br />271 <br />381 <br />203 <br />375'i <br />559' <br />Note: Match drill two holes (5/16 -inch) at <br />a distance of 3/4 -inches (19 mm) from the <br />cut end of the 45° elbow and the tee. <br />re 2.3.1 <br />NOTE: The 2.5" (64 mm) critical dimension must be inspected in the field. <br />T.1 <br />