Laserfiche WebLink
A <br />Mounting PMA <br />4 a.) The PMA mounting dware kit <br />(# 152350902) is attached to the PMA <br />packaging, it contains a gasket, a tube of <br />grease, and four 5/16" cap screws with <br />lockwashers. Remove the two packaging <br />ends and the protective sleeve from the PMA. <br />Apply grease to the pump motor, gasket, and <br />motor discharge head mounting surfaces. <br />Place the gasket on the end of the PMA, <br />aligning locating pin and bolt holes. <br />4 b.) Mount PMA onto discharge head by <br />aligning locating pin on PMA with hole in <br />discharge head, assuring that the lead <br />assembly in the motor discharge head is <br />seated in its notched position, and that the <br />PMA gasket is properly in place. Tighten <br />PMA onto discharge head using four cap <br />screws and lock washers supplied. A cross <br />bolt tightening pattern is recommended for <br />securing PMA. <br />ram <br />Motor discharge head must not be rotated <br />more than one full rotation in either direction; <br />rotating could cause damage to the electrical <br />connections in the conduit, presenting a risk <br />of lethal electrical shock or equipment failure. <br />Cam <br />Failure to push PMA up snug against the <br />discharge casting prior to tightening cap <br />screws, or failure to use a cross -pattern while <br />tightening the bolts could break the discharge <br />casting or strip the threads in the PMA. <br />m <br />The IST can be used with a PMA V62 only; the <br />PMA VS2 is different from that used on FE <br />Petro's standard pumps (e.g., STP75 and <br />STP150) and the two cannot be interchanged. <br />5 <br />STEP 4a.) <br />STEP 4b.) <br />