COMPLIANCE INFO_2007-2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3940
>
2300 - Underground Storage Tank Program
>
PR0507837
>
COMPLIANCE INFO_2007-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2024 4:41:40 PM
Creation date
6/3/2020 9:59:00 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2009
RECORD_ID
PR0507837
PE
2361
FACILITY_ID
FA0008057
FACILITY_NAME
TRACY TRUCK AND AUTO STOP
STREET_NUMBER
3940
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95304
APN
21220004
CURRENT_STATUS
01
SITE_LOCATION
3940 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0507837_3940 N TRACY_2007-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
406
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING SYSTEM CERTIFICATION ® <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7,Health and Safety Code; Chapter 16,Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be <br /> prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to <br /> the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems <br /> within 30 days of test date. <br /> A. General Information <br /> Facility Name: Tracy Truck Stop Bldg.No.: <br /> Site Address: 3940 N. Tracy Blvd. City: Tracy Zip: 95304 <br /> Facility Contact Person: Debbie Contact Phone No.:—(209) 832-5006 <br /> Make/Model of Monitoring System: Date of Testing/Servicing: 03/26/2009 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the approgriate boxes to indicatespecific a ui ment ins ected/serviced: <br /> Tank TD: 1 Regular/Premium Tank ID: 2 Diesel <br /> ❑O In-Tank Gauging Probe, Model: MAG-1 ❑x In-Tank Gauging Probe. Model: MAG-1 <br /> ❑x Annular Space or Vault Sensor. Model: 420 ®Annular Space or Vault Sensor. Model: 420 <br /> ❑O Piping Sump/Trench Sensor(s). Model: 208 x❑Piping Sump/Trench Sensor(s). Model: 208 <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> ®Mechanical Line Leak Detector. Model: LD-2000 O Mechanical Line Leak Detector. Model: LD-2000 <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify a ui ment type and model in Section E on Pa e Z). ❑ Other(specfty equipment t)Te and model in Section E on Pae 2). <br /> Tank ID: 3 Diesel Tank ID: <br /> ❑O In-Tank Gauging Probe. Model: MAG-1 ❑ In-Tank Gauging Probe. Model: <br /> ❑O Annular Space or Vault Sensor. Model: 420 ❑ Annular Space or Vault Sensor. Model: <br /> ❑O Piping Sump/Trench Sensor(s). Model: 208 ❑ Piping Sump/Trench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> ©Mechanical Line Leak Detector. Model: LD-2000 ❑ Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment t e and model in Section E on Pae 2). ❑ Other(specia equipment t e and model in Section E on Pae 2). <br /> Dispenser ID: 1-2 Dispenser ID: 3-4 <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> IK Shear Valve(s). El Shear Valve(s). <br /> ®Dispenser Containment Floats and Chain(s). 21 Dispenser Containment Floats and Chain(s). <br /> Dispenser ID: 5-6 Dispenser ID: 7-8 <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> I@ Shear Valve(s). ©Shear Valve(s). <br /> ❑X Dispenser Containment Floats and Chains . 0 Dispenser Containment Floats and Chains . <br /> Dispenser ID: 11S Dispenser ID: 11-12S <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> ©Shear Valve(s). 21 Shear Valve(s). <br /> 19 Dis enser Containment Floats and Chain(s). ❑x Dispenser Containment Floats and Chains . <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the <br /> manufacturers' guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this <br /> information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such <br /> reports,I have also attached a copy of the report;(check all that apply): ©Sys1 )ort <br /> Technician Name(print): Keith Huston Signature: <br /> Certification No.: A25577 License.No.: 880430 <br /> Testing Company Name: EPIC Compliance Systems, Inc. Phone No.: 888-700-EPIC <br /> Testing Company Address: 2400 San Bruno Ave San Francisco CA Date of Testing/Servicing: 03/26/2009 <br /> UN-036-1/4 Page 1 of 4 Rev.06/04/01 <br /> www.unidocs.org <br />
The URL can be used to link to this page
Your browser does not support the video tag.