My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3940
>
2300 - Underground Storage Tank Program
>
PR0507837
>
COMPLIANCE INFO_2007-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2024 4:41:40 PM
Creation date
6/3/2020 9:59:00 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2009
RECORD_ID
PR0507837
PE
2361
FACILITY_ID
FA0008057
FACILITY_NAME
TRACY TRUCK AND AUTO STOP
STREET_NUMBER
3940
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95304
APN
21220004
CURRENT_STATUS
01
SITE_LOCATION
3940 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0507837_3940 N TRACY_2007-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
406
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
State Water Resources Control Board Page I of 2 <br /> 40 is <br /> Home >> Water Issues -* Programs >> Ust >> Leak Prevention >> Lgl 13 >>Vendors <br /> USTProgp�T� -.L—GI .113 <br /> ........... ... —.......I....... ......-................ .......... ............ .................. .............. <br /> ... ... <br /> Issue Date:November 22,1995 <br /> Revision Date:March 11,2004 <br /> Vaporless Manufacturing <br /> Vaporless LD-3000, LD-3000S <br /> AUTOMATIC MECHANICAL LINE LEAK DETECTOR <br /> Certification Leak rate of 3.0 gph with PD = 100% and PFA = 0%. <br /> Leak 2.0 gph. <br /> Threshold A pipeline system should not be declared tight if the test result indicates a loss that equals <br /> or exceeds this threshold. <br /> Applicability Gasoline, diesel, aviation fuel. <br /> Other liquids may be tested after consultation with the manufacturer. <br /> Specification System tests pressurized steel and fiberglass pipelines. <br /> Tests are conducted at operating pressure. <br /> Pipeline Maximum of 320 gallons. <br /> Capacity <br /> Waiting Time None between dispensing and testing. <br /> Test Period Response time is 9 seconds. <br /> System Permanent installation on pipeline. <br /> Features Automatic testing of pipeline. <br /> LD3000 - restricted flow to dispenser if leak is declared. <br /> LD3000S - pump shutoff if leak is declared. <br /> Calibration Equipment must be checked annually for capability of detecting a line leak of 3.0 <br /> gph and, if necessary,calibrated in accordance with manufacturer's instructions. <br /> Comments Functionality and operability of the 99 LD-3000 are unchanged by installation of the Leak <br /> Detection Sensor(piston switch)that supports the VMI ISM-4080 and ISM-4091 Integrated <br /> Shutdown Module. <br /> Vaporless Manufacturing Evaluator: Ken Wilcox Associates <br /> 8700 East Long Mesa Drive Tel: (816)443-2494 <br /> Prescott Valley, AZ 86314 Dates of Evaluation: 08/20/93 <br /> Tel: (928)775-5191 <br /> http://www.waterboards.ca.gov/water—issues/Programs/ust/leak_prevention/lgl 13/vendors/v... 5/4/2009 <br />
The URL can be used to link to this page
Your browser does not support the video tag.