My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3940
>
2300 - Underground Storage Tank Program
>
PR0507837
>
COMPLIANCE INFO_2011-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2024 4:52:42 PM
Creation date
6/3/2020 9:59:32 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2015
RECORD_ID
PR0507837
PE
2361
FACILITY_ID
FA0008057
FACILITY_NAME
TRACY TRUCK AND AUTO STOP
STREET_NUMBER
3940
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95304
APN
21220004
CURRENT_STATUS
01
SITE_LOCATION
3940 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0507837_3940 N TRACY_2011-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
517
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A typical turbine model designation <br />" <br />has up to five components to define <br />the pump being supplied as follows: <br />N , <br />STS �C)C�CX�C Y - A B <br />STPD = Basic Model Designation <br />3 <br />X7p0A= Factory <br />Installed options <br />HCP model designations may include <br />one or more of the following <br />characters in alphabetical order: <br />AG = Alcohol -gasoline compatible <br />M (100% ethanol or methanol capable) <br />0% 15% <br />Note: Standard models to <br />ethanol or methanol capable <br />Y F = Floating suction adapter <br />(3" NPT male adapter) <br />"R = Model R check valve <br />'(24 psi relief/22 psi reset for PLLD) <br />R <br />`Note: If not otherwise specified, all <br />HCP models supplied with <br />standard model check valve <br />` (40 psi relief/35 psi reset for <br />MLD and TS-LS300). <br />Yi= Pump Motor Horsepower/ <br />Electrical Rating <br />3 = 3 hp fixed speed, 208-230 VAC <br />ll' S = 5 hp fixed speed, 208-230 VAC <br />5H = 5 hp fixed speed, 460 VAC <br />5G = 5 hp fixed speed, 575 VAC <br />q = Model Length <br />Model length is expressed as three <br />numeric characters that indicate the <br />length of the HCP from the turbine <br />manifold bottom to the pump motor <br />inlet in inches, available from 60" to <br />200" (additional charge for models <br />132" and longer). <br />B;= Riser Pipe Length <br />Riser pipe length is expressed as <br />two numeric characters that indicate <br />the total length of the riser in inches. <br />Riser pipes are available from 6" to <br />60" in three inch increments <br />3, '; (additional charge and lead time for <br />€-f risers 33" or longer). <br />High Capacity Submersible Turbine pump Specifications <br />For full diagram see page 38. <br />Power Requirements <br />• High capacity pump models require <br />three-phase, 60 Hz incoming power. <br />• High capacity pump models are <br />available as 208-230 VAC, 460 VAC or <br />575 VAC versions. <br />• High capacity pump models are available in <br />hp d 5 hp versions. <br />• S SCIII three-phase smart controllers <br />and STP-CB3/5 three-phase control boxes <br />are available for high capacity pump control. <br />Pump Motor - - <br />• Fixed speed, 3450 rpm, multi -stage <br />centrifugal type pump motor with built-in, <br />automatic, thermal overload protection. <br />• High capacity pump 60 Hz models are <br />available as two-stage versions only. <br />Liquid CompatiWINT-y <br />• Max. liquid viscosity: 70 SSU at <br />60 •F (15 °C). <br />• Standard models are UL and cUL listed for <br />fuel mixtures containing up to 15% ethanol <br />or methanol, and 20% MTBE, 20% ETBE or <br />17% TAME with gasoline. <br />• STPAG models are compatible with fuel <br />mixtures containing up to 100% ethanol or <br />methanol, and 20% MTBE, 20% ETBE or <br />17% TAME with gasoline. <br />• HCP models can also be used with diesel <br />fuels, fuel oils, kerosene, Avgas and jet fuels <br />in a non -gelled pourable state. <br />• All wetted elastomers are made -of a high <br />grade, fluorocarbon Viton- compound. <br />Standard Features <br />• Pressure relief valve: cartridge design <br />available in two pressure relief settings, <br />external to check valve. Standard model <br />relieves at 40 psi and resets above 35 psi. <br />• Syphon: external venturi-type syphon <br />primer supplied as submersible accessory. <br />• Air eliminator: every submersible <br />includes tank return path to provide active <br />air elimination. <br />Approvals <br />• Consult factory for applicable approvals. <br />Quality Certification <br />• Franklin Fueling Systems is an ISO 9001 <br />Certified Manufacturer. <br />`Viton® is a registered trademark of DuPont <br />Dow Elastomers. <br />LISTEDC YL US (9 <br />39 <br />