My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3355
>
2300 - Underground Storage Tank Program
>
PR0508352
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/8/2021 9:09:56 AM
Creation date
6/3/2020 9:59:38 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0508352
PE
2361
FACILITY_ID
FA0008044
FACILITY_NAME
CHEVRON STATION #1731*
STREET_NUMBER
3355
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95212
APN
12618007
CURRENT_STATUS
01
SITE_LOCATION
3355 E HAMMER LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0508352_3355 E HAMMER_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
492
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
E <br />E <br />CHEVRON STATION #1731* LIST Tank # CERS ID <br />3355 E HAMMER LN TA0508354 10182331 <br />STOCKTON, CA 95212 Tank info: installed Date: 7/15/1999 12:00:00 AM -Tank Use: Motor Vehicle Fueling - Tank <br />Contents: Premium Unleaded - Type Of Tank: Double Wall - Piping Construction: Double - <br />walled <br />Yes Continuous Monitoring of Piping Secondary Containment <br />Piping Secondary Containment Panel Manufacturer Leak Sensor Mf'.Lre7 r R 17 11 1 <br />Dry <br />DVEEDER-ROOT VEEDE <br />L <br />Panel Model # Leak Sensor Model # <br />TLS -350 794380-208 <br />Yes Leak Alarm Triggers Automatic Pump Shutdown A P k 10 201'1 <br />Yes Failure/Disconnect Triggers Pump Shutdown <br />- -------- --- - - ----- - <br />Mechanical Line Leak Detector Performs 3 GPH Leak Test HE <br />MLLD Manufacturer MLLD Model D E7 R - FIVI E- N T <br />-- - ---- - --------- ----------- - ----- - --------- ------ ---- - ------ - ----- -------------- ---- ----- <br />Yes Electronic Line Leak Detector Performs 3 GPH Leak Test <br />ELLD Manufacturer ELLD Programmed in -Line Testing ELLD Triggers Automatic Pump Shutdown <br />VEEDER-ROOT Yes <br />ELLD Model ELLD Failure/Disconnect Triggers Automatic Shutdown <br />PLILD Series 848480 Yes <br />- - - --------- ------------ - - - - ---------- - - - ------ <br />Pipeline Integrity Testing Visual Pipeline Monitoring <br />Pipeline Integrity Testing Frequency Visual Pipeline Monitoring Frequency <br />Suction Piping Meets Exemption Criteria <br />_ '_ ---- - ----- --------------- ----------------------------------- - --------------- ---- - --------- . . .... <br />No Regulated Piping Per Health and Safety Code, Division 20, Chapter 6.7 Is Connected To The Tank System <br />-------------- — --------- - - --- --------- - ----- -- -------- - <br />Other Pipeline Monitoring <br />UDC Monitoring Detection of Leak into UDC Triggers Audible and Visual Alarms <br />Continuous Yes <br />UDC Leak Alarm Triggers Automatic Pump Shutdown <br />UDC Panel Manufacturer Yes <br />VEEDER-ROOT Failure/Disconnection of UDC Monitoring System Triggers Automatic Pump Shutdown <br />DC Panel Model # Yes <br />TLS -350 UDC Monitoring Stops Flow of Product at Dispenser <br />UDC Leak Sensor Manufacturer <br />VEEDER-ROOT UDC Construction <br />UDC Leak Sensor Model Single -walled <br />794380-208 UDC Secondary Containment Monitoring <br />Leak Within Secondary Containment of UDC Causes Audible and Visual Alarms <br />g Ap <br />gg, <br />6*411 <br />ELD Testing <br />Yes Secondary Containment Testing <br />Yes Spill Bucket Testing <br />Printed on 3/3/2017 12:26 PM <br />X <br />win <br />
The URL can be used to link to this page
Your browser does not support the video tag.