Laserfiche WebLink
Facility/Site <br />CHEVRON STATION #1731* <br />UST Tank# CERSID <br />355 E HAMMER LN <br />TA0508353 10182331 <br />TOCKTON, CA 95212 <br />Tank Info: Installed Date: 7/1S/199912:00:00 AM -Tank Use: Motor Vehicle Fueling - Tank <br />DC Panel Manufacturer <br />Contents: Regular Unleaded -Type Of Tank: Double Wall - Piping Construction: Double - <br />EEDER-ROOT <br />walled <br />Pipe Monitoring is Performed Using the Following Method(s) <br />Yes <br />Yes Continuous Monitoring of Piping Secondary Containment <br />UDC Monitoring Stops Flow of Product at Dispenser <br />Piping Secondary Containment Panel Manufacturer <br />Leak Sensor Manufacturer <br />Dry VEEDER-ROOT <br />VEEDER-ROOT <br />Panel Model # <br />Leak Sensor Model # <br />TLS -350 <br />794380-208 <br />es Leak Alarm Triggers Automatic Pump Shutdown <br />Teak Within Secondary Containment of UDC Causes Audible and Visual Alarms <br />es Failure/Disconnect Triggers Pump Shutdown <br />Mechanical Line Leak Detector Performs 3 GPH Leak Test <br />MLLD Manufacturer MLLD Model <br />Yes Electronic Line leak Detector Performs 3 GPH Leak Test <br />ELLD Manufacturer ELLD Programmed In -Line <br />Testing ELLD Triggers Automatic Pump Shutdown <br />EEDER-ROOT <br />Yes <br />LLD Model <br />ELLD Failure/Disconnect Triggers Automatic Shutdown <br />LLD Series 848480 <br />Yes <br />Pipeline Integrity Testing <br />Visual Pipeline Monitoring <br />Pipeline Integrity Testing Frequency <br />Visual Pipeline Monitoring Frequency <br />Suction Piping Meets Exemption Criteria <br />No Regulated Piping Per Health and Safety Code, Division 20, Chapter 6.7 Is Connected To The Tank System <br />Other Pipeline Monitoring <br />Under Dispenser Containment (UDC) Monitoring <br />UDC Monitoring <br />Detection of Leak into UDC Triggers Audible and Visual Alarms <br />Continuous <br />Yes <br />UDC Leak Alarm Triggers Automatic Pump Shutdown <br />DC Panel Manufacturer <br />Yes <br />EEDER-ROOT <br />Failure/Disconnection of UDC Monitoring System Triggers Automatic Pump Shutdown <br />DC Panel Model # <br />Yes <br />LS -350 <br />UDC Monitoring Stops Flow of Product at Dispenser <br />DC Leak Sensor Manufacturer <br />EEDER-ROOT <br />UDC Construction <br />DC Leak Sensor Model <br />Single -walled <br />94380-208 <br />UDC Secondary Containment Monitoring <br />Teak Within Secondary Containment of UDC Causes Audible and Visual Alarms <br />Periodic System Testing <br />ELD Testing <br />Yes Secondary Containment Testing <br />Yes Spill Bucket Testing <br />Printed on 3/3/2017 12:26 PM <br />